Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 21 February 2010 and 22 February 2010.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Study conducted in compliance with agreed protocols/ Current OECD Guidelines and to GLP standards, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 850.6800 (Modified Activated Sludge, Respiration Inhibition Test for Sparingly Soluble Chemicals)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of GLP inspection: 15 September 2009 Date of Signature on GLP certificate:16 November 2009

Test material

Constituent 1
Reference substance name:
E0286P/040A
IUPAC Name:
E0286P/040A
Details on test material:
Sponsor's identification: E0286P/040A
Description : amber coloured viscous liquid
Batch number : E0286P/040A/01
Date received : 20 July 2009
Expiry date : 20 July 2011
Storage conditions: room temperature in the dark
The integrity of supplied data relating to the identity, purity and stability of the test item is the responsibility of the Sponsor

Sampling and analysis

Analytical monitoring:
no
Details on sampling:
Concentrations:
10, 32, 100, 320 and 1000 mg/l

Sampling method:
Observations were made on the test preparations throughout the test period. Observations of the test item vessels at 0 hours were made prior to addition of activated sewage sludge and synthetic sewage. The pH of the control, reference item and test item preparations were measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter at 0 hours and prior to measurement of the oxygen consumption rate after 3 hours contact time.

Sample storage conditions before analysis:
not specified in report

Test solutions

Vehicle:
no
Details on test solutions:
For the purpose of the test, the test item was dispersed directly in water.
Amounts of test item (5, 16, 50, 160 and 500 mg) were each separately dispersed in approximately 250 ml of water and subjected to ultrasonication for approximately 15 minutes followed by magnetic stirring for 24 hours in order to maximise the dissolved test item concentration. All test vessels were shielded from the light during mixing. Synthetic sewage (16 ml), activated sewage sludge (200 ml) and water were added to a final volume of 500 ml to give the required concentrations of 10, 32, 100, 320 and 1000 mg/l.


-Eluate:
At time "0" 16 ml of synthetic sewage was diluted to 300 ml with water and 200 ml of inoculum added in a 500 ml conical flask (first control). The mixture was aerated with clean, oil-free compressed air via narrow bore glass tubes at a rate of approximately
0.5 – 1 litre per minute. Thereafter, at 15 minute intervals the procedure was repeated with appropriate amounts of the reference item being added. The test item vessels were prepared as described in Section 3.4.1. Finally a second control was prepared.
As each vessel reached 3 hours contact time an aliquot was removed from the conical flask and poured into the measuring vessel (250 ml darkened glass Biological Oxygen Demand (BOD) bottle) and the rate of respiration measured using a Yellow Springs dissolved oxygen meter fitted with a BOD probe. The contents of the measuring vessel were stirred constantly by magnetic stirrer. The rate of respiration for each flask was measured over the linear portion of the oxygen consumption trace (where possible between approximately 6.5 mg O2/l and 2.5 mg O2/l). In the case of a rapid oxygen consumption, measurements may have been outside this range but the oxygen consumption was always within the linear portion of the respiration curve. In the case of low oxygen consumption, the rate was determined over an approximate 10 minute period.
The test was conducted under normal laboratory lighting in a temperature controlled room at 21±1DegC.

Observations were made on the test preparations throughout the test period. Observations of the test item vessels at 0 hours were made prior to addition of activated sewage sludge and synthetic sewage. The pH of the control, reference item and test item preparations were measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter at 0 hours and prior to measurement of the oxygen consumption rate after 3 hours contact time.

- Differential loading:
Not applicable.

- Controls:

The control group was maintained under identical conditions but not exposed to the test item.

- Chemical name of vehicle (organic solvent, emulsifier or dispersant):
Not applicable.

- Concentration of vehicle in test medium (stock solution and final test solution(s) including control(s)):
Not applicable.

- Evidence of undissolved material (e.g. precipitate, surface film, etc):
Observations made at 0 hours, 30 minutes and 3 hours (see Table 3) showed that the control vessels contained a dark brown dispersion and the reference item vessels contained a dark brown dispersion with no undissolved reference item visible.
Observations of the test item vessels made at 0 hours prior to the addition of activated sewage sludge and synthetic sewage showed that the test concentration of 10 mg/l contained a clear colourless water column with small particles of test item visible throughout and the test concentrations of 32, 100 and 320 mg/l contained a clear colourless water column with particles of test item visible throughout. The test concentration of 1000 mg/l contained a clear colourless water column with large particles of test item visible throughout.
Observations of the test item vessels made after 30 minutes and 3 hours contact time showed that the test concentrations of 10, 32, 100 and 320 mg/l contained a dark brown dispersion with particles of test item visible throughout. The test concentrations of 1000 mg/l contained a dark brown dispersion with large particles of test item visible throughout.

Test organisms

Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:

- Laboratory culture:
The activated sewage sludge sample was maintained on continuous aeration in the laboratory at a temperature of approximately 21ºC and was used on the day of collection. The pH of the sample was 7.4 measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter WTW pH 320 pH meter. Determination of the suspended solids level of the activated sewage sludge was carried out by filtering a sample (100 ml) of the activated sewage sludge by suction through a pre-weighed GF/A filter paper using a Buchner funnel which was then rinsed 3 times with 10 ml of deionised reverse osmosis water and filtration continued for 3 minutes. The filter paper was then dried in an oven at approximately 105ºC for at least 1 hour and allowed to cool before weighing. This process was repeated until a constant weight was attained. The suspended solids concentration was equal to 4.0 g/l prior to use.

Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Post exposure observation period:
Not applicable.

Test conditions

Hardness:
The test water used for the definitive test was laboratory tap water dechlorinated by passage through an activated carbon filter (Purite Series 500) and partly softened (Elga Nimbus 1248D Duplex water softener) giving water with a total hardness of approximately 140 mg/l as CaCO3. After dechlorination and softening the water was then passed through a series of computer controlled plate heat exchangers to achieve the required temperature. Typical water quality characteristics for the tap water as supplied, prior to dechlorination and softening, are given in Appendix 1.
Test temperature:
The test was conducted under normal laboratory lighting in a temperature controlled room at 21±1 Deg C.
pH:
The pH values of the test preparations at the start and end of the exposure period are given in Table 2.
Dissolved oxygen:
In some instances, the initial and final dissolved oxygen concentrations were below those recommended in the test guidelines (6.5 mg O2/l and 2.5 mg O2/l respectively). This was considered to have had no adverse effect on the results of the study given that in all cases the oxygen consumption rate was determined over the linear portion of the oxygen consumption trace.
Salinity:
Not applicable.
Nominal and measured concentrations:
10, 32, 100, 320 and 1000 mg/l
Details on test conditions:

TEST SYSTEM
At time "0" 16 ml of synthetic sewage was diluted to 300 ml with water and 200 ml of inoculum added in a 500 ml conical flask (first control). The mixture was aerated with clean, oil-free compressed air via narrow bore glass tubes at a rate of approximately
0.5 – 1 litre per minute. Thereafter, at 15 minute intervals the procedure was repeated with appropriate amounts of the reference item being added. The test item vessels were prepared as described in Section 3.4.1. Finally a second control was prepared.
As each vessel reached 3 hours contact time an aliquot was removed from the conical flask and poured into the measuring vessel (250 ml darkened glass Biological Oxygen Demand (BOD) bottle) and the rate of respiration measured using a Yellow Springs dissolved oxygen meter fitted with a BOD probe. The contents of the measuring vessel were stirred constantly by magnetic stirrer. The rate of respiration for each flask was measured over the linear portion of the oxygen consumption trace (where possible between approximately 6.5 mg O2/l and 2.5 mg O2/l). In the case of a rapid oxygen consumption, measurements may have been outside this range but the oxygen consumption was always within the linear portion of the respiration curve. In the case of low oxygen consumption, the rate was determined over an approximate 10 minute period.
The test was conducted under normal laboratory lighting in a temperature controlled room at 21±1Deg C.
Observations were made on the test preparations throughout the test period. Observations of the test item vessels at 0 hours were made prior to addition of activated sewage sludge and synthetic sewage. The pH of the control, reference item and test item preparations were measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter at 0 hours and prior to measurement of the oxygen consumption rate after 3 hours contact time.


TEST MEDIUM / WATER PARAMETERS
The test water used for the definitive test was laboratory tap water dechlorinated by passage through an activated carbon filter (Purite Series 500) and partly softened (Elga Nimbus 1248D Duplex water softener) giving water with a total hardness of approximately 140 mg/l as CaCO3. After dechlorination and softening the water was then passed through a series of computer controlled plate heat exchangers to achieve the required temperature. Typical water quality characteristics for the tap water as supplied, prior to dechlorination and softening, are given in Appendix 1.


OTHER TEST CONDITIONS
- Adjustment of pH:
The pH values of the test preparations at the start and end of the exposure period are given in Table 2.

- Photoperiod:
3 hours.

- Light intensity:
Normal laboratory lighting.

EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
In order to calculate the inhibitory effect of the test and reference items the respiration rate was expressed as a percentage of the two control respiration rates.

% inhibition = [ 1 – 2 RS ] x 100
RC1 + RC2
where
RS = oxygen consumption rate for test or reference sample
RC1 + RC2 = oxygen consumption rates for controls 1 and 2
The percentage inhibition values were plotted against concentration for the reference item only, a line fitted using the Xlfit software package (IDBS) and the EC15, EC20, EC50 and EC80 values determined from the equation for the fitted line.
The EC15, EC20, EC50 and EC80 values for the test item were determined by inspection of the inhibition of respiration rate data.
95% confidence limits were calculated for the reference item EC50 values using the method of Litchfield and Wilcoxon (Litchfield and Wilcoxon 1949).
The No Observed Effect Concentration (NOEC) was taken as being the EC15 value.
The results of the study are considered valid if (i) the two control respiration rates are within 15% of each other and (ii) the EC50 (3-Hour contact time) for 3,5-dichlorophenol lies within the range 5 to 30 mg/l.



TEST CONCENTRATIONS

Oxygen consumption rates and percentage inhibition values for the control, test and reference items are given in Table 1.
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol

Results and discussion

Effect concentrationsopen allclose all
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Remarks on result:
other: not specified
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Remarks on result:
other: not specified
Details on results:

Oxygen consumption rates and percentage inhibition values for the control, test and reference items are given in Table 1. The pH values of the test preparations at the start and end of the exposure period are given in Table 2, and observations made on the test preparations throughout the study are given in Table 3.
Percentage inhibition is plotted against concentration for the reference item, 3,5 dichlorophenol only (Figure 1).


The following results were derived:
E0286P/040A:
ECx (3 Hours) (mg/l) 95% Confidence Limits (mg/l)
EC20 >1000 -
EC50 >1000 -
EC80 >1000 -
NOEC 1000 -

It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/l.

3,5-dichlorophenol:
ECx (3 Hours) (mg/l) 95% Confidence Limits (mg/l)
EC20 2.3 -
EC50 7.8 6.0 - 10
EC80 26 -

Variation in respiration rates of controls 1 and 2 was ± 5% after 3 hours contact time.
The validation criteria for the control respiration rates and reference material EC50 values were therefore satisfied.




Results with reference substance (positive control):

- Results with reference substance valid?
Yes.

- Relevant effect levels:
The reference item gave a 3-Hour EC50 value of 7.8 mg/l, 95% confidence limits
6.0 - 10 mg/l.


- Other:
None.
Reported statistics and error estimates:
None.

Any other information on results incl. tables

See Overall remarks, attachements

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/l.
Executive summary:

Introduction.

A study was perford to assess the effect of the test item on the respiration of activated sewage sludge. Thethod followed that described in the OECD Guidelines for Testing of Chemicals (1984) No 209 "Activated Sludge, Respiration Inhibition Test", Method C.11 of Commission Regulation (EC) No. 440/2008 and US EPA Draft Ecological Effects Test Guidelines OPPTS 850.6800.

Methods. 

Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 32, 100, 320 and 1000 mg/l for a period of 3 hours at a temperature of 21 ± 1°C with the addition of a synthetic sewage as a respiratory substrate.

The rate of respiration was determined after 3 hours contact tiand compared to data for the control and a reference item, 3,5-dichlorophenol.

Results.

The effect of the test item on the respiration of activated sewage sludge gave a 3‑Hour EC50of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was1000mg/l.

It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/l.

The reference item gave a 3-Hour EC50value of 7.8 mg/l, 95% confidence limits
6.0 - 10 mg/l.

CONCLUSION

The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/l.