Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study was carefully performed using standard instrumentation. However, it does not cite a test guideline and the study was not done according to GLP guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
No method cited, but study used a calibrated Schott Ubbelohde capillary viscometer in a controlled-temperature bath.
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Reference substance name:
MeDONA
IUPAC Name:
MeDONA
Details on test material:
- Name of test material (as cited in study report): CF3OC3F6OCFHCF2COOCH3 PF13 Methyl Ester
- Lot/batch no.: 146830-84

Results and discussion

Viscosity
Temp.:
other: 23.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
2.43

Any other information on results incl. tables

The measured result was kinematic viscosity based on the calibration constant of 0.002545 centistokes per second. The result for dynamic viscosity was obtained by multiplying the kinematic viscosity with the density of the compound (1.589 g/mL). The density was obtained from the measured specific gravity of the compound. Only the dynamic viscosity result of 2.43 mPa∙s (cP) at 23 °C was reported. It is unknown if the the study follows an OECD, ASTM, or ISO guideline.

Applicant's summary and conclusion

Conclusions:
The viscosity of MeDONA is 2.43 mPa∙s at 23 °C.
Executive summary:

The kinematic viscosity of MeDONA was measured using a Schott AVS350 viscosity timing system with a Schott Ubbelohde-type glass capillary viscometer, type 545-03. Temperature was controlled using a Haake DC3 bath circulator/controller. Using the kinematic viscosity and density results, the dynamic viscosity of MeDONA at 23 °C was determined to be 2.43 mPa∙s (cP) at 23 °C. The study was performed using a calibrated Ubbelohde-type capillary viscometer. These types of viscometers are compliant with ASTM D445 and ASTM D446 standards. However, it is unknown if this study followed an ISO, ASTM, or OECD guideline. The study was not conducted in accord with GLP guidelines. Therefore the study is classified reliable with restrictions.