Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to an appropriate EU test method.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
DIN 51757 Oscillating densimeter
Deviations:
no
GLP compliance:
no
Type of method:
oscillating densitimeter

Test material

Constituent 1
Reference substance name:
The IUPAC name and further molecular and structural information for the reaction mass was not determinable.
Molecular formula:
The IUPAC name and further molecular and structural information for the reaction mass was not determinable.
IUPAC Name:
The IUPAC name and further molecular and structural information for the reaction mass was not determinable.

Results and discussion

Density
Type:
relative density
Density:
1.189 g/cm³
Temp.:
20 °C

Applicant's summary and conclusion