Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: the study according to Guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
Principles of method if other than guideline:
laser diffraction
GLP compliance:
yes
Type of distribution:
mass based distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Copper phtalocyanine monosulfonated and disulfonated
EC Number:
700-870-8
Molecular formula:
C32H15N8Cu(HSO3)n where n=1.3-1.6
IUPAC Name:
Copper phtalocyanine monosulfonated and disulfonated
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
- Name of test material (as cited in study report): Hyspere 12
- Molecular formula (if other than submission substance):
- Molecular weight (if other than submission substance):
- Smiles notation (if other than submission substance):
- InChl (if other than submission substance):
- Structural formula attached as image file (if other than submission substance): see Fig.
- Substance type:
- Physical state:powder
- Analytical purity:
- Impurities (identity and concentrations):
- Composition of test material, percentage of components:
- Isomers composition:
- Purity test date:
- Lot/batch No.: Batch No.1, Sample No. 1009/1
- Expiration date of the lot/batch:
- Radiochemical purity (if radiolabelling):
- Specific activity (if radiolabelling):
- Locations of the label (if radiolabelling):
- Expiration date of radiochemical substance (if radiolabelling):
- Stability under test conditions:
- Storage condition of test material:
- Other:

Results and discussion

Geometric standard deviation:
0.051
Particle size
Percentile:
D50
Mean:
>= 0.71 - <= 0.81 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all

Any other information on results incl. tables

No. 1 -3: Mean particle size-volume, Std.deviation 0.0513

No. 4 -6: Mean particle size-mass , Std. deviation 0.0115

Applicant's summary and conclusion

Conclusions:
Mass median diameter D50 is 0.26 µm. D10=0.22 µm, D90 =3.36 µm