Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999-11-23
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study, GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
2,3,7,8-tetrahydro-2,5,8-benzotrioxacycloundecine-1,9-dione
EC Number:
229-554-3
EC Name:
2,3,7,8-tetrahydro-2,5,8-benzotrioxacycloundecine-1,9-dione
Cas Number:
6607-34-7
Molecular formula:
C10H16O5
IUPAC Name:
1,4,7-Trioxacyclotridecane-8,13-dione
Details on test material:
- Name of test material (as cited in study report): Adipic acid, Cyclicester with diethylenglycol
- Analytical purity: ca. 90%
- Impurities (identity and concentrations): Diethylenglycol < 10% ; water< 2%
- Purity test date: Report of the sponsor of 18 Feb. 1999
- Lot/batch No.: B47

Sampling and analysis

Analytical monitoring:
no

Test solutions

Vehicle:
no

Test organisms

Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Preparation of inoculum for exposure: The inoculum was washed, brought to a concentration of 5 g/l dry substance and aerated for 24 hours.
- Initial biomass concentration: 50 ml were added to a total volume of 250 ml to obtain a concentration of 1 g/I dry substance in the test.

Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
30 min

Test conditions

Test temperature:
20 ± 2°C
pH:
7.1-7.2 at test start, 7.3 at test end
Dissolved oxygen:
- Oxygen concentration during aeration: >2.5 mg/I
- Oxygen concentration immediately before measurement: >6.5 mg/I
Nominal and measured concentrations:
1000 mg/l, in addition a blanc control and a reference control were tested
Details on test conditions:
TEST SYSTEM
- Test vessel:
- Type (delete if not applicable): open
- Material, size, headspace, fill volume: glass, Erlenmeyer-flask (250 ml nominal), liquid volume: 250 ml
- Aeration: sparged with air
- No. of vessels per concentration (replicates; test substance, TS): 1
- No. of vessels per control (replicates; blanc, BC): 3
- No. of vessels per concentration (replicates; positive control, reference substance, RS): 3

TEST MEDIUM / WATER PARAMETERS
- Culture medium: OECD test medium

OTHER TEST CONDITIONS
- Adjustment of pH: no pH adjustments during test

EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
O2: on line measurement for 6 min
pH: at test start and test end


Reference substance (positive control):
yes
Remarks:
3.5-dichlorophenol (CAS 591-35-5)

Results and discussion

Effect concentrations
Duration:
30 min
Dose descriptor:
other: EC20
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Results with reference substance (positive control):
- Results with reference substance valid? Yes
- Relevant effect levels: EC20 (30 min): 2.2 mg/L (nominal); EC50 (30 min): 6.5 mg/L (nominal); EC80 (30 min): 55 mg/L (nominal)

Any other information on results incl. tables

The EC20 in the activated sludge respiration inhibition test is >1000 mg/l. The inhibition of the degradation activity of activated sludge is not anticipated when introduced in appropriate low concentrations.

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Remarks:
Deviation of blank controls < 15 %; EC50 of 3,5-dichlorophenol in the range of 5-30 mg/I