Registration Dossier

Administrative data

Endpoint:
oxidising liquids
Type of information:
(Q)SAR
Adequacy of study:
key study
Study period:
15th January 2010 to 23rd February 2010.
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study conducted in accordance with generally accepted scientific principles, possibly with incomplete or methodological deficiencies, which do not affect the quality of relevant results.
Justification for type of information:
QSAR prediction: migrated from IUCLID 5.6

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Sponsor's identification : DVS005u (aka Weston 705)
Description : clear colourless viscous liquid
Batch number : MW9F23A901
Date received : 05 November 2009
Expiry date : 15 June 2010
Storage conditions : approximately 4°C, under nitrogen, in the dark

Study design

Contact with:
other: Not applicable, as determination by QSAR
Duration of test (contact time):
0 s

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other: not specified (migrated information) EXAMPLE: Example: Predicted negative based on the structure.
Parameter:
other: EXAMPLE: Example: Predicted negative based on the structure.
Remarks on result:
other: result not specified (migrated information)
Remarks:
Based on the chemical structure the result for the oxidising properties has been predicted negative.
Test results (Oxidising solids)
Sample tested:
other: not specified (migrated information) EXAMPLE: Example: Predicted negative based on the structure.
Parameter:
other: EXAMPLE: Example: Predicted negative based on the structure.
Remarks on result:
other: result not specified (migrated information)
Remarks:
Based on the chemical structure the result for the oxidising properties has been predicted negative.

Any other information on results incl. tables

The structure of the test material was assessed for chemical groups that would imply oxidising properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites. There are no such groups present in the structure.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information Based on the chemical structure
Conclusions:
Based on the chemical structure the result for the oxidising properties has been predicted negative.
Executive summary:

Method

The oxidising properties were predicted using Method A17 Oxidising Properties (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Procedure

The structure of the test material was assessed for chemical groups that would imply oxidising properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites.

Full structural details are given in Bretherick’s Handbook of Reactive Chemical Hazards, 4thEdition, Butterworths,, 1990.

Results

There are no such groups present in the structure.

 

 

Conclusion

Based on the chemical structure the result for the oxidising properties has been predicted negative.