Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Classification & Labelling & PBT assessment

GHS

Currently viewing:

General Information

Implementation:
EU
Remarks:

This classification is the official classification of the CLP Regulation, listed in its Annex VI under the Index No 607-295-00-0. It should be noted that based on the environmental evaluation and conclusion reported in the registration dossier, the substance should no more be classified as hazardous to the aquatic environment. Additionally, it should be noted that based on the revised criteria of the 2nd ATP to the CLP Regulation, the substance should not be classified as hazardous to the aquatic environment.

- For the category of self-reactive substances, no specific experimental data is available. As the substance was not found to detonate, to deflagrate rapidly or to show a violent reaction when heated in a stainless mesh cube during the self-iginition tempertaure measurement (method A16), no classification is applied for this category.

- For the category of pyrophoric solids, no specific experimental data is available but as the chemical structure of the substance gives no indication of pyrophoric properties, no classification is applied.

- For the category of substances emiting flammable gases in contact with water, as the substance is used in aqueous solution where no reaction is observed, no classification is applied.

- For the organic peroxide category, as the structure of the substance does not contain bivalent O-O structure, no classification is applied.

Classificationopen allclose all

Explosives
Reason for no classification:
data conclusive but not sufficient for classification
Flammable gases and chemically unstable gases
Reason for no classification:
data conclusive but not sufficient for classification
Aerosols
Reason for no classification:
data conclusive but not sufficient for classification
Reason for no classification:
hazard class not assessed
Oxidising gases
Reason for no classification:
data conclusive but not sufficient for classification
Gases under pressure
Reason for no classification:
data conclusive but not sufficient for classification
Flammable liquids
Reason for no classification:
data conclusive but not sufficient for classification
Flammable solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-reactive substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric liquids
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-heating substances and mixtures
Reason for no classification:
data lacking
Substances and mixtures which in contact with water emit flammable gases
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising liquids
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising solids
Reason for no classification:
data conclusive but not sufficient for classification
Organic peroxides
Reason for no classification:
data conclusive but not sufficient for classification
Corrosive to metals
Reason for no classification:
data lacking
Desensitized explosives
Reason for no classification:
data lacking
Acute toxicity - oral
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - dermal
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - inhalation
Reason for no classification:
data lacking
Skin corrosion / irritation
Reason for no classification:
data conclusive but not sufficient for classification
Serious eye damage / eye irritation
Reason for no classification:
data conclusive but not sufficient for classification
Respiratory sensitisation
Reason for no classification:
data lacking
Skin sensitisation
Hazard category:
Skin Sens. 1B
Hazard statement:
H317: May cause an allergic skin reaction.
Aspiration hazard
Reason for no classification:
data conclusive but not sufficient for classification
Reproductive toxicity
Reason for no classification:
data lacking
Effects on or via lactation
Reason for no classification:
data lacking
Germ cell mutagenicity
Reason for no classification:
data conclusive but not sufficient for classification
Carcinogenicity
Reason for no classification:
data lacking
1. Specific target organ toxicity - single (STOT-SE)
Reason for no classification:
data conclusive but not sufficient for classification
1. Specific target organ toxicity - repeated (STOT-RE)
Reason for no classification:
data conclusive but not sufficient for classification
Hazardous to the aquatic environment (acute / short-term)
Reason for no classification:
data conclusive but not sufficient for classification
Hazardous to the aquatic environment (long-term)
Hazard category:
Aquatic Chronic 2
Hazard statement:
H411: Toxic to aquatic life with long lasting effects.
Hazardous to the ozone layer
Reason for no classification:
data lacking

Labelling

Signal word:
Warning

Hazard pictogram

GHS07: exclamation mark
GHS09: environment

Hazard statements

H317: May cause an allergic skin reaction.
H411: Toxic to aquatic life with long lasting effects.

Precautionary statements

P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
P272: Contaminated work clothing should not be allowed out of the workplace.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P302+P352: IF ON SKIN: Wash with plenty of water/…
P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
P321: Specific treatment (see ... on this label).
P363: Wash contaminated clothing before reuse.
P501: Dispose of contents/container to ...
licensed facility
P273: Avoid release to the environment.
P391: Collect spillage.

Notes