Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10.09.2011 - 17.09.2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
Redox titrations are based on a reduction-oxidation reaction between an oxidizing agent and a reducing agent. A potentiometer or a redox indicator is usually used to determine the endpoint of the titration. In permanganometry a slight faint persisting pink color signals the endpoint of the titration because of the color of the excess oxidizing agent potassium permanganate
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Contact with:
potassium permanganate
Key result
Sample tested:
other: not specified
Parameter:
other: not specified
Remarks on result:
other: The substance to not show any oxidising property.
Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
According to redox titration considerations, test chemical does not possess oxidising properties. Thus, the substance is unlikely to cause or contribute to the combustion of other material during transport, storage or use.
Executive summary:

According to redox titration considerations, test chemical does not possess oxidising properties. Thus, the substance is unlikely to cause or contribute to the combustion of other material during transport, storage or use.

Description of key information

According to redox titration considerations, test chemical does not possess oxidising properties. Thus, it is unlikely to cause or contribute to the combustion of other material during transport, storage or use.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

According to redox titration considerations, test chemical does not possess oxidising properties. Thus, it is unlikely to cause or contribute to the combustion of other material during transport, storage or use.

Justification for classification or non-classification

According to redox titration considerations, test chemical does not possess oxidising properties. Thus, it is unlikely to cause or contribute to the combustion of other material during transport, storage or use.