Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.
Qualifier:
according to guideline
Guideline:
other: ASTM D 7042
Deviations:
no
GLP compliance:
no
Type of method:
other: Stabinger Viscometer
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
61.5

Description of key information

Key value for chemical safety assessment

Viscosity:
61.5 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information