Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to OECD / EU guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Atm. press.:
1 008 hPa
Remarks on result:
other: No flash point of the test item 1-bromo-3,4-dichloro-benzene was observed up to 150 °C under atmospheric conditions (1008 hPa). At 150 °C the measurement was stopped due to the high vapour pressure of the test item resulting from this temperature level.

Applicant's summary and conclusion

Conclusions:
No flash point of the test item 1-bromo-3,4-dichloro-benzene was observed up to 150 °C under
atmospheric conditions (1008 hPa). At 150 °C the measurement was stopped due to the high
vapour pressure of the test item resulting from this temperature level.