Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Remarks:
experimental data of read across substances
Justification for type of information:
Data for the target chemical is summarized based on the structurally similar read across chemicals
Reason / purpose for cross-reference:
read-across source
Reason / purpose for cross-reference:
read-across source
Reason / purpose for cross-reference:
read-across source
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
WoE report is based on four toxicity to microorganism studies as-
WoE 2, WoE 3 and WoE 4.
GLP compliance:
not specified
Analytical monitoring:
not specified
Remarks:
WoE 2: not specified, WoE 3: no and WoE 4: not specified
Vehicle:
not specified
Test organisms (species):
other: WoE 2 and WoE 3: activated sludge of a predominantly domestic sewage and WoE 4: anaerobic bacteria
Test type:
not specified
Water media type:
not specified
Total exposure duration:
3 h
Remarks on exposure duration:
WoE 2 and WoE 3: 3 hr, WoE 4: 24 hr
Reference substance (positive control):
not specified
Duration:
3 h
Dose descriptor:
EC0
Effect conc.:
500 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks on result:
other: WoE 2
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 500 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks on result:
other: WoE 2
Duration:
3 h
Dose descriptor:
EC0
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks on result:
other: WoE 3
Duration:
24 h
Dose descriptor:
EC10
Effect conc.:
> 5 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition
Remarks on result:
other: WoE 4
Validity criteria fulfilled:
not specified
Conclusions:
On the basis of the various experimental studies of the structurally and functionally similar read across chemical and applying the weight of evidence approach and by evaluating the effect of test chemical on test organism, the 3 hr EC50 value can be expected to be > 500 mg/l.
Executive summary:

Data available of the structurally and functionally similar read across chemicals has been reviewed to determine the effect of the test chemical on toxicity to microorganisms or activated sludge. The studies are as mentioned below:

Toxicity study to activated sludge was carried out for 3 hrs for assessing the effect of test chemical. The study was performed in accordance with the OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test. Activated sludge, predominantly domestic sewage was used as a test organism. On the basis of the effect on respiration rate of the test inoculum, the 3 hr EC0 and EC50 value was determined to be 500 and >500 mg/l, respectively.

Another toxicity study to activated sludge was carried out for 3 hrs for assessing the effect of test chemical. The study was performed following the principles of the OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test. Activated sludge, predominantly domestic sewage was usedas a test organism. Test chemical concentrations were not analytically verified. On the basis of the effect on respiration rate of the test inoculum, the 3 hr EC0 value was determined to be >1000 mg/l (nominal concentrations).

For the test chemical, toxicity study to anaerobic bacteria was carried out for 24 hrs for assessing the effect of test chemical. On the basis of the effect on growth inhibition of the test bacteria, the 24 hr EC10 value was determined to be >5000 mg/l.

On the basis of the various experimental studies of the structurally and functionally similar read across chemical and applying the weight of evidence approach and by evaluating the effect of test chemical on test organism, the 3 hr EC50 value can be expected to be > 500 mg/l.

Description of key information

On the basis of the various experimental studies of the structurally and functionally similar read across chemical and applying the weight of evidence approach and by evaluating the effect of test chemical on test organism, the 3 hr EC50 value can be expected to be > 500 mg/l.

Key value for chemical safety assessment

EC50 for microorganisms:
500 mg/L

Additional information

Data available of the structurally and functionally similar read across chemicals has been reviewed to determine the effect of the test chemical on toxicity to microorganisms or activated sludge. The studies are as mentioned below:

 

Toxicity study to activated sludge was carried out for 3 hrs for assessing the effect of test chemical. The study was performed in accordance with the OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test. Activated sludge, predominantly domestic sewage was used as a test organism. On the basis of the effect on respiration rate of the test inoculum, the 3 hr EC0 and EC50 value was determined to be 500 and >500 mg/l, respectively.

 

Another toxicity study to activated sludge was carried out for 3 hrs for assessing the effect of test chemical. The study was performed following the principles of the OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test. Activated sludge, predominantly domestic sewage was usedas a test organism. Test chemical concentrations were not analytically verified. On the basis of the effect on respiration rate of the test inoculum, the 3 hr EC0 value was determined to be >1000 mg/l (nominal concentrations).

 

For the test chemical, toxicity study to anaerobic bacteria was carried out for 24 hrs for assessing the effect of test chemical. On the basis of the effect on growth inhibition of the test bacteria, the 24 hr EC10 value was determined to be >5000 mg/l.

 

On the basis of the various experimental studies of the structurally and functionally similar read across chemical and applying the weight of evidence approach and by evaluating the effect of test chemical on test organism, the 3 hr EC50 value can be expected to be > 500 mg/l.