Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 Dec 2004 to 16 Dec 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
Version / remarks:
1986 (E) (Method B)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
- Name of test material (as cited in study report): Butanediolmonoacrylate
- Batch number: 010078 EDA 0
- Aggregate state: liquid
- Analytical purity: 99.3 corrected peak area-%
- Homogeneity: homogeneous
- Expiry date: May 2005
- Stability: guaranteed by sponsor
Analytical monitoring:
no
Vehicle:
no
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Source: Activated sludge from laboratory wastewater plant treating municipal sewage.
- Concentration of dry substance: 1 g/L.
- Preparation of the inoculum: inoculum was washed and brought to a concentration of 5 g/L dry substance and aerated over night. 50 mL were added to a total volume of 250 mL to obtain a concentration of 1 g/L dry substance in the test.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
30 min
Test temperature:
20 ± 2 °C
pH:
- pH value at test start (after correction): 7.1 - 7.2
- pH value after 30 min: 7.3 - 7.5
Dissolved oxygen:
- During aeration: >2.5 mg/L
- Immediately before measurement: > 6.5 mg/L
Nominal and measured concentrations:
- Nominal test concentrations: 0 (control), 100, 248, 496, and 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: erlenmeyer-vessel
- Test volume: 250 mL

TEST MEDIUM / WATER PARAMETERS
- Synthetic medium: 8 mL/vessel 100-fold concentrated OECD medium

EFFECT PARAMETERS MEASURED: oxygen consumption
- Duration of the measurement of oxygen : 8 - 10 min
Reference substance (positive control):
yes
Remarks:
3,5-Dichlorophenol
Key result
Duration:
30 min
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Duration:
30 min
Dose descriptor:
other: EC20
Effect conc.:
ca. 320 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Duration:
30 min
Dose descriptor:
other: EC80
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
Inhibition of the respiration rate was 10% in the 100 mg/L dose group and increased in a dose-dependent manner up to 48% inhibition at the dose group of 1000 mg/L. For an overview of the results, see 'Any other information on results incl. tables'.
Results with reference substance (positive control):
The 30-min EC50 of the reference substance was determined to be ca. 9 mg/L.

Table: Respiration rate after 30 min of incubation.

Nominal Conc. [mg/l]

O2 consumption rate [mg O2/L*h]

Change in O2 consumption rate [%]

0 (control)

21*

-

100

19

10

248

18

14

496

15

29

1000

11

48

* mean value of blank control (3 replicates)

 

Validity criteria fulfilled:
yes
Remarks:
see 'Any other information on materials and methods incl. tables'.
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Qualifier:
according to guideline
Guideline:
ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
GLP compliance:
not specified
Specific details on test material used for the study:
- Name of test material (as cited in study report): Butanediolmonoacrylate
Analytical monitoring:
no
Vehicle:
no
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Source: Activated sludge from a laboratory waste water treatment plant treating municiple waste water.
- Initial biomass concentration: Concentration of activated sludge: 1 g/L dry matter
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
30 min
Nominal and measured concentrations:
- Nominal test concentrations: 0 (control), 100 and 1000 mg/L
Reference substance (positive control):
not specified
Duration:
30 min
Dose descriptor:
other: EC20
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
At 100 mg/L, 14% of respiration inhibition was observed. No inhibition of respiration was observed at 1000 mg/L, however. See 'Any other information on results incl. tables'.

Table: Respiration rate after 30 min of incubation.

Nominal Conc. [mg/l]

DOC conc. [mg/L]

Respiration rate [mg/L x h]

Respiration inhibition [%]

0

-

22

-

100

58.1

25

14

1000

583.1

22

-

 

 

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
without detailed documentation.
Qualifier:
according to guideline
Guideline:
DIN 38412-8 (Pseudomonas Zellvermehrungshemmtest)
GLP compliance:
not specified
Specific details on test material used for the study:
- Name of test material (as cited in study report): Butanediolmonoacrylate
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
- Concentration of the stock solution: 12500 mg/L.

Test organisms (species):
Pseudomonas putida
Details on inoculum:
- Strain: DSM 50026
Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
7 h
Test temperature:
297 ± 1 K
Nominal and measured concentrations:
- Nominal test concentrations: 0 (control), 78.125, 156.25, 312.5, 625, 1250, 2500, 5000, and 10000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: Erlenmeyers (300 mL)
- Used volume: 100 mL test media
- Shaking conditions: yes

TEST MEDIUM / WATER PARAMETERS
- Medium: AK-medium according to DIN 38412 part 8
- Stock solution: concentration 12500 mg/L

TEST SOLUTION
- 0.5 mL nutrient solution I (20 fold)
- 0.5 mL nutrient solution II (20 fold)
- 1 mL bacteria suspension
- 8 mL test substance solution
Reference substance (positive control):
no
Duration:
7 h
Dose descriptor:
EC10
Effect conc.:
343.6 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition
Duration:
7 h
Dose descriptor:
EC50
Effect conc.:
842.3 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition
Duration:
7 h
Dose descriptor:
other: EC90
Effect conc.:
1 320.1 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition

Table: growth inhibition after 7 hours exposure.

Nominal Conc. [mg/l]

Growth inhibition in % of the control

78.125

108.64

156.25

100.3

312.5

92.1

625

71.01

1250

10.57

2500

0.44

5000

0.10

10000

0.10

Description of key information

The 30-min EC50 value is >1000 mg/L as observed in a respiration inhibition study with activated sludge treating domestic sewage.

Key value for chemical safety assessment

EC50 for microorganisms:
1 000 mg/L

Additional information

The toxicity of 4-hydroxyethyl acrylate to microorganisms was investigated in three different studies according to OECD guideline 209 guideline and DIN 38412 Part 8.

The study conducted most recent was in compliance with GLP regulations and performed according to OECD guidelines and therefore selected as key study. The toxicity of the substance to microorganisms was investigated in an activated sludge respiration inhibition study according to OECD TG 209 and in compliance with GLP criteria (BASF, 2005). In this study, non-adapted activated sludge treating domestic sewage was exposed to nominal test substance concentrations of 0 (control), 100, 248, 496, and 1000 mg/L for 30 minutes. Test concentrations were not analytically verified. The effects on microorganisms was determined by measuring total respiration rates and comparing these to an unexposed control. Inhibition of respiration rates was first observed from the lowest test concentration of 100 mg/L (10%). The effects increased concentration-dependently reaching 48% at the highest concentration tested. Based on these findings, the 30-min EC50 and EC20 values were determined at >1000 mg/L and ca. 320 mg/L, respectively.

In a supporting study, performed according to OECD 209, domestic activated sludge was exposed to nominal test concentrations of 0 (control), 100 and 1000 mg/L for 30 minutes (BASF, 1989). At 100 mg/L, the inhibition was determined to be 14%. No inhibition of respiration was measured at 1000 mg/L, however. The 30-min EC20 value was determined to be >1000 mg/L.

In the other study, bacteria (Pseudomonas putida) were exposed to nominal test substance concentrations of 0 (control), 78.125, 156.25, 312.5, 625, 1250, 2500, 5000, and 10000 mg/L for 7 hours (BASF, 1989). The inhibition of growth increased in a dose-dependent manner from 312.5 mg/L up to 10000 mg/L. The EC50 and EC10 values were determined to be 842.3 mg/L and 343.6 mg/L, respectively.