Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: In case of unconsciousness place patient in recovery
position and obtain immediate medical attention. Supply
fresh air.
Emergency measure - Eyes: Irrigate open eye for 15 minutes under running water. Obtain
immediate medical attention.
Emergency measure - Skin: Immediately wash with soap and water and rinse thoroughly.
Seek medical advice.
Emergency measure - Ingestion: Do not induce vomiting, call for medical help immediately.
Rinse out mouth and drink plenty of water.

Fire-fighting measures

Recommended extinguishing agent: Dry sand, foam, carbon dioxide, or dry chemical powder
extinguisher should be used.

Product arising from burning: The substance is combustible and will burn if involved in a
fire, evolving noxious fumes (eg carbon oxides). However,
there is no experimental evidence to support the anticipated
combustion products.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards as
mentioned in section 2.3.10.


Avoid dust formation by damping down with water. Absorb
spillages of solutions with a suitable inert material (eg
sand or soil). Carefully transfer the spillage to waste
containers, or use a sealed industrial vacuum machine.
Containers filled with waste material must be labelled in
the same way as the original containers.


Clean the spillage area with water and detergent.


Dispose of waste material by incineration in accordance with
local regulations.

Handling and storage

Handling: The substance should be stored, handled and used in
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.


Engineering controls are necessary to reduce exposure to the
substance.


When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.
Such protective equipment should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166


When necessary appropriate respiratory protection should be
used. e.g. a dust mask conforming to EN149 FFP1.


The standards mentioned above should be regarded as a
minimum.

Storage: Store in a cool, dry, well-ventilated area.


Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: The preparation is packed into either one gallon (3.78
litre) or one quart (0.946 litre) bottles, which are then
put in a cardboard box.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: None.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None which is hazardous.

Dust explosion: There is a potential for dust explosion from the substance
as it is an organic powder. However, as the substance is
imported as part of a liquid preparation, there is no risk
of dust explosion.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery from minor spillages or accidental discharge is not
economically or technically feasible, and such waste
material will be disposed of by incineration. In principle,
it may be possible to recover larger spillages of
uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: None known

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
must be scrubbed, because noxious fumes (eg carbon oxides)
could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to
the sewage system or the aqueous environment. However,
adverse effects on sewage treatment systems would be
unlikely.

Industry - Possibility of destruction - other: None known.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.