Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07 October 1995
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed in accordance with EU test guidelines in complaince with GLP.
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

ADK STAB HP-10 could not be ignited with a flame.

The test substance melted and emitted sparks in contact with the ignition source.

During the ignition of the test substance some sparks were observed.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
In conclusion, AOK STAB HP-10 is not "highly flammable" according to the criteria as described in the method A.10 of EEC-Directive 92/69 EEC.
Executive summary:

The determination of the flammability of ADK STAB HP-10 was performed in accordance with EEC-Directive 92/69 EEC, A.10 "Flammability (solids)” (1992).

 

ADK STAB HP-10 was formed in a wedge-shaped pile with a length of 25 cm, a width of 2 cm and 1 cm in height. An attempt was made to ignite the test substance with a flame of a gas-burner.

The test substance could not be ignited with a flame.

The test substance melted and emitted sparks in contact with the ignition source.

During the ignition of the test substance some sparks were observed.

 

In conclusion, ADK STAB HP-10 is not "highly flammable" according to the criteria of the directive.

Description of key information

Key value determined using EU Method A10.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

ADK STAB HP-10 was formed in a wedge-shaped pile with a length of 25 cm, a width of 2 cm and 1 cm in height. An attempt was made to ignite the test substance with a flame of a gas-burner.

The test substance could not be ignited with a flame.

The test substance melted and emitted sparks in contact with the ignition source.

During the ignition of the test substance some sparks were observed.

 

In conclusion, ADK STAB HP-10 is not "highly flammable" according to the criteria of the directive.

Justification for classification or non-classification

Based on the information available the substance does not trigger any of the requirements for classification.

The registered substance is therefore Not Classified.