First-aid measures

Emergency measure - Inhalation: Remove to fresh air. Symptomatic treatment. Seek immediate
medical attention.
Emergency measure - Eyes: Wash eyes immediately with plenty of water for at least 15
minutes. Seek immediate medical attention.
Emergency measure - Skin: Wash skin thoroughly with soap and plenty of water. Seek
medical attention.
Emergency measure - Ingestion: Wash mouth out with water (only if person is conscious) and
seek immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry powder, foam

Product arising from burning: The substance is flammable and will burn if involved in a
fire, evolving extremely noxious fumes (eg hydrogen
chloride, phosgene and carbon oxides). However, there is no
experimental evidence to support the anticipated combustion
products.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards as
mentioned in section 2.3.10.


Absorb spillages of solutions with a suitable inert material
(eg sand or soil). Carefully transfer the spillage to waste
containers, or use a sealed industrial vacuum machine.
Containers filled with waste material must be labelled in
the same way as the original substance containers.


Clean the spillage area with water and detergent.


Dispose of waste material by incineration in accordance with
local regulations.

Handling and storage

Handling: The substance should be stored, handled and used in
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.


When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.
Such protective equipmemt should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166


When necessary appropriate respiratory protection should be
used. e.g. a respirator conforming to EN12941.


The standards mentioned above should be regarded as a
minimum.

Storage: Store in a dry well-ventilated area, away from sources of
ignition.


Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: Mild steel drum (45 gallon).

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: UN Class 6, Division 6.1 Poisonous (Toxic) substances, PG II
Transport: Also Class 8 Corrosives, Packing Group (PG) II or IIIa.


Keep the container closed.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Dangerous reactions may occur with the following;


acids

bases

ammonia

amines

sodium (plus alloys of)

zinc (plus alloys of)

magnesium (plus alloys of)

halides


May undergo autopolymerisation.

Chemical reaction with water: None

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery from minor spillages or accidental discharge is not
economically or technically feasible, and such waste
material will be disposed of by incineration. In principle,
it may be possible to recover larger spillages of
uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: The substance is considered hazardous to health and the
environment.


No chemical treatment is practicable to neutralise the
hazardous properties.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
must be scrubbed, because extremely noxious fumes (eg
hydrogen chloride, phosgene and carbon oxides) could be
formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to
the sewage system or the aqueous environment. However,
adverse effects on sewage treatment systems would be
unlikely.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: None.