Registration Dossier

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 03 April 2007 and 24 April 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report Date:
2007

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 92/69/EEC, A16
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Sponsor's identification: C-Y9
Description : yellow powder
Lot number : MB-1
Date received : 06 March 2007
Storage conditions: room temperature in the dark over silica gel.

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 400 °C
Remarks on result:
other: Pressure inot indicated.
Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 400 °C
Remarks on result:
other: Pressure inot indicated.

Any other information on results incl. tables

Observations after the test:

The cube contained black charred remains.

Applicant's summary and conclusion

Conclusions:
The test material has been determined not to have a relative self-ignition temperature below 400°C.
Executive summary:

Method:

The test material was heated in an oven and the relative self ignition temperature determined. Testing was conducted using Method A16 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).

Conclusion:

The test material has been determined not to have a relative self-ignition temperature below 400°C.