Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to an appropriate EU test method, and in compliance with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
ISO 2719
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
72 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: corrected value

Any other information on results incl. tables

Test conditions:

Humidity (rel.): 46%

Room temperture: 21,8°C

Atmospheric pressure: 96 kPa

Applicant's summary and conclusion