Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: If inhaled, remove to fresk air; if still having difficulty
breathing, seek medical attention.
Emergency measure - Eyes: Flush eyes with plenty of water, if irritation persists,
seek medical attention.
Emergency measure - Skin: Flush affected area with plenty of water.
Emergency measure - Ingestion: If swallowed, seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: water

Product arising from burning: CO, CO2, NO2 and SO2

Product determined by test: N

Protective equipment: Normal protective equipment while fighting fires should be
used, including self-contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Before picking up spill, wear minimum personal protective
equipment. For large spills a higher level of personal
protective equipment may be needed.

Sweep and shovel spill into an empty plastic-lined
container.

Secure cover on waste container and identify for chemical
waste disposal via appropriate corporate procedure.

Do not mix picked-up spills of different chemicals together.

Flush contaminated area with water ONLY AFTER spill has been

picked up; use sufficient water.

Handling and storage

Handling: Material should be handled with good ventilation, eye
glasses and gloves are required.

Respiratory protection should be worn if dust generation is
expected to occur.

Storage: Material should be stored at room temperature.

Packaging of the substance and or preparation: Polyethylene lined drums (55 gallons), containing about
200-220 kg of a 50% aqueous solution of the notified
substance.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: none

Chemical reaction with water: none, substance is soluble in water.

Dust explosion: Organic powders if dispersed in air may form explosive dust
concentrations; standard precautions should be observed.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery by mechanical collection (611)

Industry - Possibility of neutralisation: not applicable

Industry - Possibility of destruction: controlled discharge: not applicable

Industry - Possibility of destruction - incineration: Incinerator with flue gas scrubbing (661).

Note that the material will be imported as a 50% aqueous
solution. In order to destroy it should preferably be
concentrated before incineration.

Industry - Possibility of destruction - water purification: not applicable

Industry - Possibility of destruction - other: not applicable

Public at large - Possibility of recovery/recycling: not applicable

Public at large - Possibility of neutralisation: not applicable

Public at large - Possibility of destruction: controlled discharge: not applicable

Public at large - Possibility of destruction - incineration: At users discretion - Incinerate, not specified (660).

Public at large - Possibility of destruction - water purification: not applicable

Public at large - Possibility of destruction - others: When the product is discarded in the end use, it can be
disposed of with regular household waste, both the picture