Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20018-11-22
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Percentile:
D50
Mean:
15.52 µm
Remarks on result:
other: one measurement
Conclusions:
The test item is a powder with a D50 of 15.52 µm measured via laser diffraction.

Description of key information

The test item is a powder with a D50 of 15.52 µm measured via laser diffraction.

Additional information