Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 428-040-8 | CAS number: 138261-41-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 3 Mar 2021
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) - Method B: Fibre Length and Diameter Distributions
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
- Qualifier:
- according to guideline
- Guideline:
- ISO 13320 (Particle size analysis - Laser diffraction methods)
- Qualifier:
- according to guideline
- Guideline:
- other: CIPAC MT 187
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Hessisches Ministerium für Umwelt, Energie, Jugend, Familie und Gesundheit, Wiesbaden, Germany
- Type of method:
- Laser scattering/diffraction
- Type of distribution:
- volumetric distribution
- Percentile:
- D50
- Mean:
- 9.8 µm
- Remarks on result:
- other: standard deviation not reported
- Percentile:
- D10
- Mean:
- 2.7 µm
- Remarks on result:
- other: standard deviation not reported
- Percentile:
- D90
- Mean:
- 28.1 µm
- Remarks on result:
- other: standard deviation not reported
Reference
Results:
The test item consisted of transparent particles which appeared
irregular formed.
The test item was sieved with a mesh size of 1000 pm. 98.7 % (w/w) of
the test item passed the sieve and only this fraction was measured with
laser diffraction.
The particles were introduced to the analyser beam by the dry powder
feeder by direct spraying through the measurement area. The powder was
loosened by an integrated vibrator. The particles were dispersed and fed
to the optical system by pressurized dry air (1.5 bar). After passing
the analyser beam the sample was collected in a vacuum cleaner. After
adjusting the laser, measuring the background and adjusting the correct
particle concentration (obscuration) the measurement was started. The
control software automatically performed three measurements. The average
of these three measurements was given as result. Two test series of
three measurements each were performed. The measurement time was 8 s.
Individual results:
D50: 9.77 µm (1st test series), 9.82 µm (2nd test series)
D10: 2.64 µm (1st test series), 2.67 µm (2nd test series)
D90: 28.26 µm (1st test series, 27.95 µm (2nd test series)
Description of key information
The results of the laser diffraction experiment, volumetric distribution
(CIPAC MT 187, ISO13320 and under consideration of OECD 110 and US
EPA OCSPP 830.7520):
D50: 9.8 µm
D10: 2.7 µm
D90: 28.1 µm
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.