Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Vapour pressure
Administrative data
Link to relevant study record(s)
- Endpoint:
- vapour pressure
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 15 July to 25 August 2010
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Remarks:
- The study was conducted according to an internationally recognised method, and under GLP, but accuracy is limited by measuring range and extrapolation. The substance is adequately identified, but the composition is incomplete. Therefore validation applies with restrictions.
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 104 (Vapour Pressure Curve)
- Version / remarks:
- 23. Mar. 2006
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.4 (Vapour Pressure)
- Version / remarks:
- Regulation (EC) N°440/2008, as modified by Reg.(EC) No 761/2009
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- issued on 12/01/2007
- Type of method:
- effusion method: Knudsen cell
- Specific details on test material used for the study:
- Storage condition of test material: The test item was stored in a closed vessel at room temperature (20 +/-5°C).
- Test no.:
- #1
- Temp.:
- 20 °C
- Vapour pressure:
- 0.138 Pa
- Key result
- Test no.:
- #2
- Temp.:
- 25 °C
- Vapour pressure:
- 0.223 Pa
- Conclusions:
- Low volatility (based on volatility bands criteria for occupational exposure (Chesar / ECETOC TRA), << 500 Pa).
- Executive summary:
The vapour pressure of test item was measured under GLP according to OECD 104 / EU A4 guideline, effusion method with Knudsen cell (weight loss).
Determinations were conducted at 30 and 45°C, with triplicate measurements for each of the four cells.
The vapour pressure at 25°C of the test item was extrapolated from the regression as 0.223 Pa.
Reference
Table 4.6/1: Vapour Pressures (Effusion Method)
Experiment No. |
T (°C) |
T (K) |
P (Pa) |
Stand. Dev. P (Pa) |
RSD P (%) |
1 |
30 |
303.2 |
0.356 |
0.111 |
31.2 |
2 |
45 |
318.2 |
1.32 |
0.197 |
15.0 |
Vapour pressure at two different temperatures was examined. For these temperatures, 1/T was plotted against log (P):
log (VP) = -3649.4 x (1/T) + 11.59
The linear regression gave a correlation coefficient r of - 1, as only two experiments could be performed for the test item.
For the test item, the following vapour pressures at 20 °C and at 25 °C were calculated from the regression equation:
Vapour pressure at 20 °C: 0.138 Pa
Vapour pressure at 25 °C: 0.223 Pa
Description of key information
Low volatility.
Key value for chemical safety assessment
- Vapour pressure:
- 0.223 Pa
- at the temperature of:
- 25 °C
Additional information
A reliable experimental study, conducted according to a recognized EC method and under GLP, is available.
Despite restrictions due to technical inaccuracy and incomplete test item identification, it is considered as key study, and the result is retained as key data.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.