Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Justification for type of information:
Performed to accepted ASTM method, but full details not reported.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
11.35 mmS at 40 C

Test material

Constituent 1
Chemical structure
Reference substance name:
Isoalkanes, C17 -C22 linear and branched
EC Number:
954-736-0
Molecular formula:
C17H36 x C22H46
IUPAC Name:
Isoalkanes, C17 -C22 linear and branched
Test material form:
liquid
Specific details on test material used for the study:
Referred to as RKSAT22

Results and discussion

Flash point
Flash point:
ca. 165 °C
Atm. press.:
ca. 1 atm

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Results are in line with expected figure for this class of hydrocarbon.