Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
not specified
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
other: Gallenkamp flashpoint device (autoflash AF3)

Test material

Constituent 1
Chemical structure
Reference substance name:
1,6-anhydro-β-D-glucose
EC Number:
207-855-0
EC Name:
1,6-anhydro-β-D-glucose
Cas Number:
498-07-7
Molecular formula:
C6H10O5
IUPAC Name:
(1R,2S,3S,4R,5R)-6,8-dioxabicyclo[3.2.1]octane-2,3,4-triol
Constituent 2
Chemical structure
Reference substance name:
Glycollaldehyde
EC Number:
205-484-9
EC Name:
Glycollaldehyde
Cas Number:
141-46-8
Molecular formula:
C2H4O2
IUPAC Name:
2-hydroxyacetaldehyde
Constituent 3
Reference substance name:
Organic acids
IUPAC Name:
Organic acids
Constituent 4
Reference substance name:
Ketones
IUPAC Name:
Ketones
Constituent 5
Reference substance name:
Phenols
IUPAC Name:
Phenols
Constituent 6
Reference substance name:
Water
EC Number:
231-791-2
EC Name:
Water
Cas Number:
7732-18-5
Molecular formula:
H2O
IUPAC Name:
water
Constituent 7
Reference substance name:
Oligomers of sugars and anhydrosugars
IUPAC Name:
Oligomers of sugars and anhydrosugars
Test material form:
liquid: viscous

Results and discussion

Flash point
Key result
Flash point:
91 °C
Atm. press.:
1 013 hPa

Any other information on results incl. tables

 Replicate  Flashpoint (C)
 1  91
 2  92
 3  91

Applicant's summary and conclusion

Conclusions:
The average flashpoint of the test item was 91°C
Executive summary: