Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) - Method B: Fibre Length and Diameter Distributions
Version / remarks:
Adopted, 12 May 1981
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Mass median aerodynamic diameter:
3.296 µm
Geometric standard deviation:
0.56
Percentile:
D10
Mean:
0.843 µm
St. dev.:
0.18
Key result
Percentile:
D50
Mean:
3.296 µm
St. dev.:
0.56
Percentile:
D90
Mean:
16.87 µm
St. dev.:
1.5
Conclusions:
The particle size distribution of test item was determined and the testing results were: D10 is 0.843 um, D50 is 3.296 um, D90 is 16.87 um.

Description of key information

The particle size distribution of test item was determined and the testing results were: D10 is 0.843 um, D50 is 3.296 um, D90 is 16.87 um.

Additional information