Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Phase 09 July 2020 to 10 July 2020.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The pile melted but failed to ignite during the 2 minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item has been determined not to be highly flammable as it failed to ignite in the preliminary screening test.
Executive summary:

Introduction

The flammability of the test substance was assessed using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Method

A preliminary test was conducted on the substance as follows: A mould (250 mm long x 20 mm wide x 10 mm high) was loosely filled with test item. A non-combustible, non-porous board was placed onto the mould which was then inverted. The mould was removed and an air-rich Bunsen burner flame applied to one end of the pile for two minutes.

Results

The pile melted but failed to ignite during the 2 minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

Conclusion

The test item has been determined not to be highly flammable as it failed to ignite in the preliminary screening test.

Description of key information

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test item has been determined not to be highly flammable as it failed to ignite in the preliminary screening test.