Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes
Type of method:
gas saturation method

Test material

Reference
Name:
Unnamed
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Purity : 99.5 % w/w

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
< 0.012 other: mPa
Test no.:
#2
Temp.:
40 °C
Vapour pressure:
< 0.03 other: mPa

Applicant's summary and conclusion

Conclusions:
The vapour pressure tests were performed on the test sample at 25°C (298 K) and 40°C (313 K) with a 20 mL/min nitrogen flow rate.
The vapour pressure at 25°C is P<0.012 mPa (log P < -1.927)
The vapour pressure at 40°C is P<0.030 mPa (log P < -1.529)