Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
October 12, 2016 - November 21, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Version / remarks:
adopted 28 July 2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
Version / remarks:
30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
BASF SE, Experimental Toxicology and Ecology, 67056 Ludwigshafen, Germany

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: CA AQ02372

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature
- Stability under test conditions: The stability under storage conditions over the study period was guaranteed by the sponsor.



In vitro test system

Test system:
human skin model
Remarks:
EpiDermTM model
Source species:
human
Cell type:
non-transformed keratinocytes
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm model EPI-200
- Tissue batch number(s): 23362

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37°C
- Temperature of post-treatment incubation (if applicable): 37°C

REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: washed with PBS
- Observable damage in the tissue due to washing: no

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1.0 mg / mL MTT diluent
- Incubation time: 3 hours
- Spectrophotometer: Sunrise Absorbance Reader
- Wavelength: 570 nm
- Filter: Measurement using a filter wavelength 570 nm without reference filter

NUMBER OF REPLICATE TISSUES: 2

CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
- killed tissues
- Procedure used to prepare the killed tissues (if applicable): freeze-killed
- N. of replicates : 2 per exposure time

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 45%. In addition, those materials with a viability of ≥ 50% after 3 min treatment are considered as corrosive if the mean relative tissue viability after 1 hour treatment with a test material is decreased below 15%.
- The test substance is considered to be non-corrosive to skin if the viability after 3 minutes exposure is greater than 55% and the viability after 1 hour exposure is greater than 20%.]

Mean tissue viability
(% of negative control) Prediction
3 min: < 45 Corrosive (Optional Sub-category 1A)*
3 min: 45 - 55 Borderline#
3 min: > 55 and 1 hour: 10 - 2 Borderline#
3 min: > 55 and 1 hour: < 1 Corrosive (Optional Sub-category 1B and 1C)
3 min: > 55 and 1 hour: > 20 Non-corrosive

- Justification for the selection of the cut-off point(s) if different than recommended in TG 431 and 439:
*According to the current OECD Guideline 431 a sub-categorization is possible based on the results. However, the sub-categorization into 1A is highly over-predictive as stated in the guideline and differentiation into sub-category 1B or 1C is not possible.
#The „borderline“-evaluation (50 ± 5% and 15 ± 5%) was determined statistically using historic BASF data and hence considers the variance of the test method. This evaluation is an amendment to the evaluation provided in OECD Guideline 431.

Control samples:
yes, concurrent negative control
yes, concurrent positive control
yes, concurrent MTT non-specific colour control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 50 µL

NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL

POSITIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL
Duration of treatment / exposure:
3 min and 1 hour
Number of replicates:
2

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
exposure period 3 min
Value:
97
Negative controls validity:
valid
Remarks:
100%
Positive controls validity:
valid
Remarks:
21.5%
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
exposure period 1 hour
Value:
70.9
Negative controls validity:
valid
Remarks:
100%
Positive controls validity:
valid
Remarks:
4.3%
Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: no
- Direct-MTT reduction: no
- Colour interference with MTT: no

DEMONSTRATION OF TECHNICAL PROFICIENCY: yes

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes
- Acceptance criteria met for positive control: yes
- Acceptance criteria met for variability between replicate measurements: yes

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met