Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 April 2018 to 23 July 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Council Regulation 440/2008, 4 March 2016
Deviations:
no
GLP compliance:
yes (incl. certificate)
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Specific details on test material used for the study:
Identification: Photomer 4250
Appearance: Colourless to pale yellow liquid
Flash point:
186 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test substance was found to be 186 °C at 1013 hPa, under the conditions of the test.
Executive summary:

In this guideline (EU A.9) study, conducted with GLP certification, the flash point of the test substance was found to be 186 °C at 1013 hPa.

Description of key information

Study conducted to recognised testing guidelines [with GLP certification].

Key value for chemical safety assessment

Flash point at 101 325 Pa:
186 °C

Additional information