Registration Dossier

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 438 (Isolated Chicken Eye Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Qualifier:
according to
Guideline:
EU method B.48 (Isolated chicken eye test method for identifying occular corrosives and severe irritants)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Test animals / tissue source

Species:
chicken
Details on test animals or tissues and environmental conditions:
SOURCE OF COLLECTED EYES
- Source: TARAVIS KFT. 9600 Sárvár, Rábasömjéni út 129. Hungary
- Storage, temperature and transport conditions of ocular tissue: Head collection was performed by a slaughter house technician. Heads were removed immediately after sedation of the chickens (sedation was happened by electric current). The heads were transported to Toxi-Coop ZRT. at the earliest convenience for use approximately within 2 hours from collection. The ambient temperature was optimal (19.3ºC to 20.4 ºC) during the transport. All eyes used in the assay were from the same groups of eyes collected on one specific day.
- Time interval prior to initiating testing: 2 h
- indication of any existing defects or lesions in ocular tissue samples: After collection, the heads were inspected for appropriate quality and wrapped with paper moistened with saline, then placed in a plastic box that can be closed (4-5 heads/box).

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
TEST MATERIAL
- Amount applied: The test item was applied in such a way that the approximately 2 cm^2 entire surface of a plastic film was covered with test substance.
Duration of treatment / exposure:
10 sec
Duration of post- treatment incubation (in vitro):
The control and test item treated eyes were evaluated pre-treatment and at approximately 30, 75,120, 180 and 240 minutes after the post-treatment rinse. Minor variations within ± 5 minutes were considered acceptable.
Number of animals or in vitro replicates:
3
Details on study design:
SELECTION AND PREPARATION OF ISOLATED EYES
After removing the head from the plastic box, it was put on soft paper. The eyelids were carefully cut away with scissors, avoiding damaging the cornea. One small drop of fluorescein solution 2 % (w/v) was applied onto the cornea surface for a few seconds and subsequently rinsed off with 20 mL saline solution. Then the fluorescein-treated cornea was examined with a slit lamp microscope, with the eye in the head, to ensure that the cornea was not damaged (i.e., fluorescein retention ≤ 0.5). If the cornea was in good condition, the eyeball was carefully removed from the orbit. The eye ball was carefully removed from the orbit by holding the nictitating membrane with a surgical forceps, while cutting the eye muscles with bent scissors. Care was taken to remove the eyeball from the orbit without cutting off the optical nerve too short. The procedure avoided pressure on the eye while removing the eyeball from the orbit, in order to prevent distortion of the cornea and subsequent corneal opacity.Once removed from the orbit, the eye was placed onto damp paper. The nictitating membrane and other connective tissue were cut away. The prepared eyes were kept on wet papers in a closed box to maintain an appropriate humidity. The treatment group and the concurrent positive control consisted of three eyes. The negative control group consisted of one eye. The enucleated eye was placed in a steel clamp with the cornea positioned vertically with the eye in the correct relative position (same position as in the chicken head). Again, too much pressure on the eye by the clamp was avoided. Because of the relatively firm sclera of the chicken eyeball, only slight pressure was needed to fix the eye properly. The clamp with the eyeball was transferred to a chamber of the superfusion apparatus. The clamp holding the eye was positioned in such a way that the entire cornea was supplied with saline solution dripping from a stainless steel tube, at a rate of approximately 3 or 4 drops/minute. The door of the chamber was closed except for manipulations and examinations, to maintain temperature and humidity. The appropriate number of eyes was selected and, after being placed in the superfusion apparatus, the eyes were examined again with the slit lamp microscope to ensure that they were in good condition. The focus was adjusted to see clearly the saline solution which was flowing on the cornea surface. Eyes with a high baseline fluorescein staining (i.e., > 0.5) or a high corneal opacity score (i.e., > 0.5) were rejected. The cornea thickness was measured using the depth measuring device. Any eye with cornea thickness deviating more than 10 % from the mean value for the eyes, or eyes that showed any other signs of damage, were rejected and replaced. If the selected eyes were appropriate for the test, acclimatisation started and was conducted for approximately 45 to 60 minutes. The temperature of the circulating water was verified to ensure that the temperature in all chambers was in the range of 32 ± 1.5 °C during the acclimatisation and treatment periods.

EQUILIBRATION AND BASELINE RECORDINGS
At the end of the acclimatization period, a zero reference measurement was recorded for cornea thickness and opacity to serve as a baseline (t=0) for each individual eye. The cornea thickness of the eyes should not change by more than ±5-7 % within approximately 45 to 60 minutes before the start of application. Slight changes in thickness (0% to 2%) were observed in the eyes, finding considered as normal when maintaining enucleated eyes. Following the equilibration period, the fluoresce in retention was measured. Baseline values were required to evaluate any potential test item related effects after treatment. The location of any minor findings was marked on the record sheet as a drawing, if applicable. If any eye was considered to be unsuitable following baseline assessment, it was discarded.

NUMBER OF REPLICATES: 3

NEGATIVE CONTROL USED: NaCl (9 g/L saline)

POSITIVE CONTROL USED: Acetic acid 10 % (v/v)

APPLICATION DOSE AND EXPOSURE TIME: 2 cm^2 for 10 sec

OBSERVATION PERIOD: up to 240 min

REMOVAL OF TEST SUBSTANCE
- Volume and washing procedure after exposure period: The time of application was monitored.After an exposure period of 10 seconds the cornea surface was rinsed thoroughly with 20 mL saline solution at ambient temperature, while taking care not to damage the cornea but attempting to remove the entire residual test item, if possible. The eye in the holder was then returned to its chamber. The time while the eye was out of the chamber was limited to a minimum.

SCORING SYSTEM:
- Mean corneal swelling (%)
- Mean maximum opacity score
- Mean fluorescein retention score at 30 minutes post-treatment

DECISION CRITERIA: decision criteria as indicated in the TG was used.

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
percent corneal swelling
Remarks on result:
other: results not yet available
Irritation parameter:
cornea opacity score
Remarks on result:
other: results not yet available
Irritation parameter:
fluorescein retention score
Remarks on result:
other: results not yet available

Applicant's summary and conclusion

Conclusions:
The eye irritation potential of the test item will be determined.
Executive summary:

A study will be performed in accordance with OECD TG 438 in order to determine the eye irriation potential of the test item. The results will be updated as soon as available.The study was initiated in January 2020 but was not completed by the CRO in due time to complete the registration dossier. The study record will be updated as soon as the results will become available.