Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16-09-2019 to 16-10-2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study performed under GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Deviations:
no
GLP compliance:
yes
Type of method:
air comparison pycnometer (for solids)
Type:
relative density
Density:
1.4 other: dimensionless
Temp.:
20 °C
Type:
density
Density:
1.4 g/cm³
Temp.:
20 °C

Determination 1: 1.402 at 20°C

Determination 2: 1.396 at 20°C

The individual measurements were obtained with an accuracy of < 0.02 g/cm3. According to the guideline, the density of the test item is given as the mean value.

Conclusions:
The relative density of the test item was determined to be 1.40 at 20 °C.
Executive summary:

The relative density was determined using EU Method A.3, OECD Method 109 and EPA OPPTS 830.7300 gas comparison pycnometer method under GLP. The relative density of the test item has been determined to be 1.40 at 20 °C.

Description of key information

Relative Density: 1.40 at 20 °C, EU Method A.3 / OECD 109 / EPA OPPTS 830.7300 – gas comparison pycnometer method, 2019.

Key value for chemical safety assessment

Relative density at 20C:
1.4

Additional information

Key study : EU Method A.3 / OECD 109 / EPA OPPTS 830.7300, 2019 : The relative density was determined using EU Method A.3, OECD Method 109 and EPA OPPTS 830.7300 gas comparison pycnometer method under GLP. The relative density of the test item has been determined to be 1.40 at 20 °C.