Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: isothermal thermogravimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid: viscous
Specific details on test material used for the study:

Aggregate State at Room Temperature: Liquid
Colour: Colourless to yellowish
Expiry / Retest Date: November 22, 2019
Storage Conditions at Test Facility: At 20°C +/- 5°C in the dark

Results and discussion

Vapour pressure
Key result
Temp.:
ca. 20 °C
Vapour pressure:
ca. 0 Pa

Applicant's summary and conclusion

Conclusions:
According to OECD 104, the vapour pressure of the test item is 2.07E-4 Pa at 20°C.