Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 1996-01-04 to 1996-05-09
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
GLP study in accordance with recognised test guideline but: Lot/batch No.: not stated Expiration date of the lot/batch: not stated NOTE: study deemed acceptable because spectral data for A-3622 are available, covering before and after the test period - see section 1.4 Analytical Information.
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
- Substance type: Organic
- Physical state: Solid
- Composition of test material, percentage of components: relative proportions components 1, 2 and 3 are 100:60:40
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
negative (not further specified)
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N

Thermal sensitivity - Koenen test

Nozzle plate orifice diameter

T1 (seconds)

T2 (seconds)

6 mm 

 

 

Test 1

Test 2

Test 3

12

11

11

300

300

300

2 mm 

 

 

Test 1

Test 2

Test 3

10

15

8

300

300

300

Where T1 = time from start of test to flame from nozzle

T2 = time from start of test to explosion, or end of test (300 seconds)

Mechanical sensitivity (shock) - BAM Fall hammer test

Result: 0,0,0,0,0,0

Where 0 = No evidence of ignition or explosion.

Mechanical sensitivity (friction) - BAM Friction test

Result: 0,0,0,0,0,0

Where 0 = No evidence of ignition or explosion.

Interpretation of results:
other: not explosive
Conclusions:
The test item is not explosive.
Executive summary:

Explosivity due to thermal and mechamical sensitivity was determined in accordance with EEC Method A14. The test item is not explosive.

Description of key information

Explosivity due to thermal and mechamical sensitivity was determined in accordance with EEC Method A14. The test item is not explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

The test item is not explosive according to EEC Method A14.

Therefore, in accordance with Regulation (EC) No. 1272/2008 section 2.1.2, this substance shall not be classified as explosive.