First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Rinse with plenty of water, for at least 15 minutes. Seek
medical attention.
Emergency measure - Skin: Wash affected area with plenty of water. If irritation
persists seek medical attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, dry chemical or foam may be used.

Product arising from burning: Products of combustion may contain oxides of carbon and
nitrogen together with hydrogen fluoride gas and metal
oxides smoke.

Product determined by test: N

Protective equipment: Full protective clothing including a self-contained
breathing apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing (see 2.3.1). Vacuum or
sweep up material, minimising dust, and transfer solid
material to a suitable container and dispose of by
incineration in accordance with local regulations. The spill
site should be washed with water, taking care not to
discharge washings to watercourses.

Handling and storage

Handling: Ensure adequate ventilation.

Protective overalls, gloves, safety glasses and respiratory
protection (HEPA-filter, full face or half mask respirator)
should be worn.

Storage: Store in tightly closed plastic containers in a cool, dry
place.

Packaging of the substance and or preparation: 25 and/or 50 kg sealed fibre drums with a polyethylene inner
lining.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility. Waste gas
treatment to remove oxides of nitrogen and hydrogen fluoride
gas should be fitted. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.