Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove the person to fresh air. Give oxygen or artificial
respiration if needed. Seek medical attention.
Emergency measure - Eyes: Flush eye immediately with plenty of water for 15 minutes.
Seek medical attention.
Emergency measure - Skin: Flush skin immediately with plenty of water. Seek medical
attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry chemical, alcohol and universal foam,
and water spray.

Product arising from burning: May generate oxides of nitrogen and sulphur, and carbon
dioxide.

Product determined by test: N

Protective equipment: Fire-fighters should wear self contained breathing
apparatus.

Accidental release measures

Emergency measures in case of spillage: Eliminate all ignition sources. Sweep up into containers
and seal. Dispose of material in accordance with government
requirements and ensure conformity to local disposal
regulations.

Handling and storage

Handling: The preparation containing the substance will only be used
in the industry by trained personnel. Exposure is minimal.
Inhalation and skin contact are avoided by the use of
impermeable protective gloves and dust masks. Dust-proof
filling apparatus and appropriate ventilation are also used.

Storage: The preparation containing the test substance should be kept
in securely closed unbreakable containers. Keep away from
foodstuffs and sources of ignition.

Packaging of the substance and or preparation: The preparation is packaged into either one gallon or one
quatro glass containers.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: The preparation should be kept in an appropriate, tightly
closed container during transport, away from light in a cool
(<20 deg C) place. Containers should be stored upright and
secured against falling over. Containers should be suitably
labelled and sealed.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion: Not anticipated.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: The preparation is not recovered or recycled during normal
use.


Any spilled material is not recovered but is disposed of by
incineration or disposal to landfill in accordance with
local regulations.

Industry - Possibility of neutralisation: Not known.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of the preparation
mixed with inert material (e.g. sand or soil) may be
disposed of at an authorised tip in accordance with local
regulations.

Industry - Possibility of destruction - incineration: Incineration is the preferred method of disposal. The
preparation may be disposed of by burning under controlled
conditions at a licensed waste treatment processor in
accordance with local regulations. Stack gases should be
scrubbed as noxious fumes (e.g. carbon dioxide) could be
formed. Incineration is the preferred method of disposal .

Industry - Possibility of destruction - water purification: In the unlikely event that the preparation should enter the
water treatment system, contaminated waste water should be
treated by means of flocculation precipitation. The
precipitated material should then be incinerated.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable as the substance/preparation is not available
to the general public.