Registration Dossier

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. QA statement)
Type of method:
buoyancy method - hydrostatic balance
Type:
bulk density
Density:
1.018 g/cm³
Temp.:
20 °C

Using a measuring probe with a density of 2.330 g/mL, density measurement was performed on the sample. The temperature of the sample was maintained through the use of a circulating water bath to the temperature jacket sample holder accessory, in order to achieve a sample temperature of 20°C ± 1°C. The sample temperature was recorded immediately after each measurement using a long stem thermometer (Fisher FB61328, 255LN) that has an accuracy of ± 0.2°C. Based on historical data from the theoretical values of water, the density results are estimated to be ± 0.5%.

Conclusions:
Bulk density of the test material was determined to be 1.018 g/cm3 using hydrostatic balance method.
Executive summary:

Bulk density of the test material was determined to be 1.018 g/cm3 using hydrostatic balance method.

Description of key information

Bulk density of the test material was determined to be 1.018 g/cm3 using hydrostatic balance method.

Key value for chemical safety assessment

Relative density at 20C:
1.018

Additional information