Registration Dossier

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04.06.2018- 07.06.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
The test is conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A.3 and OECD Test Guideline 109.
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Specific details on test material used for the study:
Sample dried and then ground in a coffee grinder.
Key result
Type:
relative density
Remarks:
(D20 4)
Density:
1.831 other: N/A
Temp.:
20 °C
Key result
Type:
density
Density:
1 831 kg/m³
Temp.:
20 °C
Conclusions:
Relative density: 1.831
Test Item density: 1831 kg.m-3 @ 20°C

Description of key information

Relative density (D204) 1.831

Test Item density 1831 kg.m-3 @ 20°C

Key value for chemical safety assessment

Relative density at 20C:
1.831

Additional information