Registration Dossier

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Fresh air; if necessary seek medical advice.
Emergency measure - Eyes: Rinse with plenty of water
Emergency measure - Skin: Wash with plenty of water and soap
Emergency measure - Ingestion: Seek medical advice or poisson information center, if
possible show label.

Fire-fighting measures

Recommended extinguishing agent: All extingushing agent are suitable.

Product arising from burning: CO, CO2, NOx, SO2, HCN

Product determined by test: N

Protective equipment: Self-contained respirator

Accidental release measures

Emergency measures in case of spillage: If accidentally spilled take up mechanically with e.g.
dustpan, broom, industrial vacuum cleaner, recycle and
discharge. During the taking up follow the precautions,
disribed in 2.3.1.

Handling and storage

Handling: Usual precaution for handling chemical should be taken into
acount. All filling stations have to be exhausted; during
handling greater amounts of the dye wear gloves and dust
mask. Avoid inhalation of the substance; possiblity of
sensitation of the respiratory tract for some reactive dyes.

Storage: Store dry and only in closed packages. Remove product
residues from the packages. Store the liquid preparation
cool (0-25 °C).

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Transport only in closed containers and safe from falling.
Proctect powder from moisture. Transport liquid preparations
cool (0-25 °C).
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None

Chemical reaction with water: No reactions

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery by solid/liquid separation (623)

Industry - Possibility of neutralisation: Not applicable

Industry - Possibility of destruction: controlled discharge: not applicable

Industry - Possibility of destruction - incineration: Incinerator with flue gas scrubbing

(661 )

Industry - Possibility of destruction - water purification: Removal by controlled discharge to a waste water treatment
plant/ preliminary cleaning with activated charcoal

( 641 )

Public at large - Possibility of recovery/recycling: Not applicable