Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Reference substance name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
EC Number:
943-693-3
IUPAC Name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
Test material form:
liquid
Details on test material:
- Name.of test material: Ammonium bis (tartrato) diantimonate (I) solution
- Purity: Water 55%, Ammonium bis (tartrato) diantimonate (1) 27%, Diammonium tartrate 19%
- Batch No.: 150492F01

Results and discussion

Viscosityopen allclose all
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
4.68
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
2.79
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.58
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.16

Any other information on results incl. tables

Viscosity determination of the test item at 20 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

3.5835

4.6750

2nddetermination

3.5843

4.6761

Mean value

3.58

4.68

*)calculated with a density of the test item ofρ= 1.304595 g/ml

 

Viscosity determination of the test item at 40 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

2.1547

2.7870

2nddetermination

2.1591

2.7927

Mean value

2.16

2.79

*)calculated with a density of the test item ofρ= 1.293435 g/ml

The estimated accuracy is ± 1 %.

Applicant's summary and conclusion