Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Abel apparatus

Test material

Constituent 1
Reference substance name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
EC Number:
943-693-3
IUPAC Name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
Test material form:
liquid
Details on test material:
- Name.of test material: Ammonium bis (tartrato) diantimonate (I) solution
- Purity: Water 55%, Ammonium bis (tartrato) diantimonate (1) 27%, Diammonium tartrate 19%
- Batch No.: 150492F03

Results and discussion

Flash pointopen allclose all
Key result
Remarks on result:
no flash point according to standard method
Remarks:
DIN EN ISO 13736 (Able, closed cup): No flashpoint detected, ignition flame expires at aoorox. 53 °C
Key result
Remarks on result:
no flash point according to standard method
Remarks:
DIN EN ISO 2719 (Pensky-Martens, closed cup): No flashpoint detected, ignition flame expires at approx. 48 °C

Any other information on results incl. tables

Results

Test method

Flashpoint in °C

 DIN EN ISO 2719

 No flashpoint detected, ignition flame expires at approx. 48 °C

 DIN EN ISO 13736

 No flashpoint detected, ignition flame expires at aoorox. 53 °C

No flashpoint bas been detected for tbe test substance.

Applicant's summary and conclusion