Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Abel apparatus

Test material

Constituent 1
Reference substance name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
EC Number:
943-693-3
IUPAC Name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
Test material form:
liquid
Details on test material:
- Name.of test material: Ammonium bis (tartrato) diantimonate (I) solution
- Purity: Water 55%, Ammonium bis (tartrato) diantimonate (1) 27%, Diammonium tartrate 19%
- Batch No.: 150492F03

Results and discussion

Flash pointopen allclose all
Key result
Remarks on result:
no flash point according to standard method
Remarks:
DIN EN ISO 13736 (Able, closed cup): No flashpoint detected, ignition flame expires at aoorox. 53 °C
Key result
Remarks on result:
no flash point according to standard method
Remarks:
DIN EN ISO 2719 (Pensky-Martens, closed cup): No flashpoint detected, ignition flame expires at approx. 48 °C

Any other information on results incl. tables

Results

Test method

Flashpoint in °C

 DIN EN ISO 2719

 No flashpoint detected, ignition flame expires at approx. 48 °C

 DIN EN ISO 13736

 No flashpoint detected, ignition flame expires at aoorox. 53 °C

No flashpoint bas been detected for tbe test substance.

Applicant's summary and conclusion