Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From July 29, 2019 to August 19, 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test O.1 (Test for oxidizing solids)
GLP compliance:
yes
Contact with:
powdered cellulose
Duration of test (contact time):
3 min
Key result
Sample tested:
1:1 sample-to-cellulose ratio
Parameter:
burning rate
Result:
> 180 s
Remarks on result:
fuming
Key result
Sample tested:
4:1 sample-to-cellulose ratio
Parameter:
burning rate
Result:
> 180 s
Remarks on result:
fuming
Sample tested:
reference: 3:7 mixture potassium bromate + cellulose
Parameter:
mean burning time
Result:
98.2 s
Remarks on result:
flaming
Sample tested:
reference: 2:3 mixture potassium bromate + cellulose
Parameter:
mean burning time
Result:
55.6 s
Remarks on result:
flaming
Sample tested:
reference: 3:2 mixture potassium bromate + cellulose
Parameter:
mean burning time
Result:
4.8 s
Remarks on result:
flaming

Table 1. Burning time for reference item and cellulose mixture

 Sr. No.       Replication              Ratio wise burning rate (sec)
 3:7  2:3  3:2
 1  R1  98  57  4
 2  R2  101  55  5
 3  R3  97  56  6
 4  R4  99  54  4
 5  R5  96  56  5
    Mean Burning time (sec)  98.2  55.6  4.8

Table 2. Burning time for test item and cellulose mixture

 Sr. No.     Replication        Ratio wise burning rate (sec)
 4:1  1:1
 1  R1 Not ignited and burned 
 2  R2
 3  R3
 4  R4
 5  R5
Interpretation of results:
GHS criteria not met
Conclusions:
Test item and cellulose both mixture (4:1 and 1:1 ratio) showed as not ignited and burned. The oxidizing properties of CR SR94 was assessed and classified under Not Division 5.1 category.
Executive summary:

This study was performed as per UN Test O.1 guideline. The Oxidizing Properties of the test item was determined by using test item and cellulose powder mixture in the ration of 4:1 and 1:1 by weight basis. Test item and cellulose both mixture (4:1 and 1:1 ratio) showed as not ignited and burned. The oxidizing properties of CR SR94 was assessed and classified under Not Division 5.1 category.

Description of key information

Test item and cellulose both mixture (4:1 and 1:1 ratio) showed as not ignited and burned. The oxidizing properties of CR SR94 was assessed not classified.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

This study was performed as per UN Test O.1 guideline. The Oxidizing Properties of the test item was determined by using test item and cellulose powder mixture in the ration of 4:1 and 1:1 by weight basis. Test item and cellulose both mixture (4:1 and 1:1 ratio) showed as not ignited and burned. The oxidizing properties of CR SR94 was assessed and classified under Not Division 5.1 category.

Justification for classification or non-classification