Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 607-033-5 | CAS number: 223749-05-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Skin irritation / corrosion
Administrative data
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2018-12-10 - 2019-02-20 (experimental phase)
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- GLP
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 019
- Report date:
- 2019
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Version / remarks:
- OECD Guidelines for the Testing of Chemicals Part 431, adopted 29. Jul. 2016
“In vitro Skin Corrosion: reconstructed human epidermis (RHE) test method” - Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
- Version / remarks:
- Commission Regulation (EU) No.440/2008, EU-Method B.40 BIS. “IN VITRO SKIN CORROSION: HUMAN SKIN MODEL TEST“ dated 30. May 2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Landesamt für Umwelt, Kaiser-Friedrich-Straße 7, 55116 Mainz, Germany
Test material
- Reference substance name:
- Yucca schidigera, ext.
- EC Number:
- 607-033-5
- Cas Number:
- 223749-05-1
- IUPAC Name:
- Yucca schidigera, ext.
- Test material form:
- solid: particulate/powder
- Remarks:
- fine beige
- Details on test material:
- Storage: Room Temperature (20 ± 5 °C)
Homogeneity: homogeneous
Constituent 1
- Specific details on test material used for the study:
- The test item was stored in the test facility in a closed vessel at room temperature (20±5°C).
In vitro test system
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Source strain:
- other: not applicable
- Justification for test system used:
- First step in top-down approach; in vitro test as indicated in the REACH Regulation.
- Vehicle:
- water
- Remarks:
- Defined amounts of the test item were applied together with 25 µL demineralised water.
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: The test system is a commercially available EpiDermTM-Kit, procured by MatTek. The EpiDermTM tissue consists of human-derived epidermal keratinocytes which have been cultured to form a multi-layered, highly differentiated model of the human epidermis. It consists of organized basal, spinous and granular layers, and a multi-layered stratum corneum containing intercellular lamellar lipid layers arranged in patterns analogous to those found in vivo. The EpiDermTM tissues are cultured on specially prepared cell cultures inserts.
- Tissue batch number(s): 28675, 28683
- Delivery date: 11. Dec. 2018 (EPI-200-SIT, Batch 28675), 12. Feb. 2019 (EPI-200-SCT, Batch 28683)
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37 ± 1°C
- Temperature of post-treatment incubation (if applicable): 37 ± 1°C
REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: The inserts were thoroughly rinsed with DPBS.
- Observable damage in the tissue due to washing: none stated
- Modifications to validated SOP: none stated
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: A MTT stock solution of 5 mg/mL in DPBS buffer was prepared and stored in aliquots of 2 mL in the freezer (– 20±5°C).
One aliquot of the stock solution was thawed and diluted with 8 mL of medium. This MTT-solution with the resulting concentration of 1 mg/mL was used in the test.
- Incubation time: 3h
- Spectrophotometer: Anthos Reader 2010 Flexi
- Wavelength: 570 nm
NUMBER OF REPLICATE TISSUES: 2 per test
CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
- Fresh tissues / killed tissues: In addition to the normal test procedure described, the functional check employed two freeze-killed tissues treated with the MTT reducing test item (for 3 minutes and 1 hour experiment) and two untreated killed tissues (for 3 minutes and 1 hour experiment) that showed the small amount of MTT reduction due to residual NADH and associated enzymes within the killed tissues
- Procedure used to prepare the killed tissues (if applicable): Freeze killed tissues were prepared by placing untreated tissues in freezer (– 20 ± 5°C) over night. Once killed, the tissues were stored indefinitely in the freezer.
- N. of replicates : 2
- Method of calculation used: The mean value “% Viability (freeze-killed-tissues)” of the additional test was subtracted from the mean value “% Viability” of the main test to achieve the corrected tissue viability.
NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 1
PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.
- The test substance is considered to be non-corrosive to skin if the viability after 3 minutes exposure is greater than or equal to 50% and the viability after 1 hour exposure is greater than or equal to 15%. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): ca. 25 mg test item were applied together with 25 µL demineralised water
NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL demineralised water
POSITIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL potassium hydroxide solution (8 M) - Duration of treatment / exposure:
- 3 min or 1 h
- Duration of post-treatment incubation (if applicable):
- Incubation with MTT solution for 3 hours
- Number of replicates:
- 2 x 2 tissues
Results and discussion
In vitro
Resultsopen allclose all
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- test item, mean, 3 min incubation
- Value:
- 91.2
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- test item, mean, 1 h incubation
- Value:
- 69.7
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- - OTHER EFFECTS:
- Visible damage on test system: none stated
- Direct-MTT reduction: The resulting solution was colourless, therefore no binding capacity had to be tested.
- Colour interference with MTT: The MTT solution changed its colour to purple within 1 hour, so the test item had shown its ability to reduce MTT
DEMONSTRATION OF TECHNICAL PROFICIENCY:
The validity of the skin corrosion study at LAUS GmbH was demonstrated in a proficiency study. For this purpose, 12 proficiency chemicals (indicated by the OECD 431 guideline) were tested.
All of the 12 proficiency chemicals were correctly categorized.
Therefore, the proficiency of the skin corrosion study was demonstrated.
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes
- Acceptance criteria met for positive control: yes
- Acceptance criteria met for variability between replicate measurements: yes
- Range of historical values if different from the ones specified in the test guideline: no
Applicant's summary and conclusion
- Interpretation of results:
- study cannot be used for classification
- Remarks:
- non-corrosive
- Conclusions:
- The study was conducted under GLP according to OECD guideline 431 on the registered substance itself. The method is to be considered scientifically reasonable with no deficiencies in documentation. The validity criteria are fulfilled, positive and negative controls gave the appropriate response. Hence, the results can be considered as reliable to assess the corrosive potential of the test substance to the skin in vitro.
The mean value of relative tissue viability of the test item was reduced to 85.9% after 3 minutes treatment. This value is above the threshold for corrosivity (50%). After 1 hour treatment, the mean value of relative tissue viability of the test item was reduced to 56.4%, lying above the threshold for corrosivity (15%). Therefore, the test item is considered as non-corrosive to skin.
In a tiered in vitro testing strategy, this result (non-corrosive) may however only give an indication of the skin-damaging potential, but does not allow a definitive classification according to Regulation 1272/2008. So, an additional skin irritation test should be conducted. - Executive summary:
One valid experiment of the main test was performed according to OECD TG 431 under GLP.
Two experiments of the additional test were performed.
The first experiment of the additional test was not valid, because the standard deviation of the replicates of the test item in the 1 hour experiment was 61.2%, required is ≤30%. The first experiment of the additional test is not reported in this report, but the raw data are kept in the test facility in the GLP- archive.
The second experiment of the additional test was valid and the results are reported here.
In the pre-test the test item showed MTT-reducing properties. The probability to influence the photometric measurement had to be excluded. Therefore, an additional test using freeze-killed tissues that possess no metabolic activity, but absorb and bind the test item like viable tissues was performed. The result of the additional test showed that MTT reduction by the test item did not influence the result of the study.
In the main test two tissues of the human skin model EpiDerm were treated with the test item for 3 minutes and 1 hour, respectively. The test item was applied to each tissue and spread to match the tissue size.
Demineralised water was used as negative control, 8 M KOH was used as positive control.
After treatment, the respective substance was rinsed from the tissues. Then, cell viability of the tissues was evaluated by addition of MTT, which can be reduced to a blue formazan. Formazan production was evaluated by measuring the optical density (OD) of the resulting solution.
After treatment with the negative control, the absorbance values were within the required acceptability criterion of mean OD ≥ 0.8 and ≤ 2.8 for both treatment intervals thus showing the quality of the tissues. The OD was 1.7 (3 minutes experiment) and 1.6 (1 hour experiment).
The positive control showed clear corrosive effects for both treatment intervals. The mean relative tissue viability value was reduced to 5.7% for the 1 hour treatment.
After 3 minutes treatment with the test item, the mean value of relative tissue viability was reduced to 85.9%. This value is above the threshold for corrosion potential (50%). After 1 hour treatment, mean value of relative tissue viability was reduced to 56.4%. This value, too, is above the threshold for corrosion potential (15%).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.