Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
other: Handbook data
Adequacy of study:
key study
Study period:
unkown
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
Method not reported. Handbook data.
GLP compliance:
not specified
Type of method:
other: Handbook data only. No guideline or method is indicated.
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: result extrapolated from series of measurements at higher temperatures

The value is extrapolated from 10 vapour pressure values covering temperatures from 115 to 287.5 °C:

T [°C] VP [mm Hg]
115 1
143.2 5
157 10
174 20
192 40
203 60
217.4 100
240 200
263 400
287.5 760

The Handbook reports 10 different vapour pressures for different temperatures. Based on this temperatures a vapour pressure for 25 °C can be extrpolated:

1 / T [°C]

Log VP

0.00869565

0.00

0.00698324

0.70

0.00636943

1.00

0.00574713

1.30

0.00520833

1.60

0.00492611

1.78

0.00459982

2.00

0.00416667

2.30

0.00380228

2.60

0.00347826

2.88

Based on these values the equation y = -550.58x + 4.5883 can be set (R² =0.9797) and the vapour pressure at 25 °C can be caluclated:

T [°C]

1 / T [°C]

Log VP (extrapolated)

VP (extrapolated) [mm Hg]

20

0.05

-22.9407

1.089E-10

25

0.04

-17.4349

2.680E-08

50

0.02

-6.4233

1.623E-03

The extrapolated vapour pressure of the test item is 2.680E-08 mmHg (=3.57E-06 Pa) at 25 °C.

Conclusions:
The extrapolated vapour pressure of the test item is 2.680E-08 mmHg (=3.57E-06 Pa) at 25 °C.
Executive summary:

The extrapolated vapour pressure of the test item is 2.680E-08 mmHg (=3.57E-06 Pa) at 25 °C.

T [°C] VP [mm Hg]
115 1
143.2 5
157 10
174 20
192 40
203 60
217.4 100
240 200
263 400
287.5 760

The Handbook reports 10 different vapour pressures for different temperatures. Based on this temperatures a vapour pressure for 25 °C can be extrpolated:

1 / T [°C]

Log VP

0.00869565

0.00

0.00698324

0.70

0.00636943

1.00

0.00574713

1.30

0.00520833

1.60

0.00492611

1.78

0.00459982

2.00

0.00416667

2.30

0.00380228

2.60

0.00347826

2.88

Based on these values the equation y = -550.58x + 4.5883 can be set (R² =0.9797) and the vapour pressure at 25 °C can be caluclated:

T [°C]

1 / T [°C]

Log VP (extrapolated)

VP (extrapolated) [mm Hg]

20

0.05

-22.9407

1.089E-10

25

0.04

-17.4349

2.680E-08

50

0.02

-6.4233

1.623E-03

Description of key information

The vapour pressure of the test item is 2.680E-08 mmHg (=3.57E-06 Pa) at 25 °C.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information