Administrative data

First-aid measures

Emergency measure - Inhalation: Symptomatic treatment.

Emergency measure - Eyes: Rinse with plenty of water.

Emergency measure - Skin: Wash with soap and water.

Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, foam or dry powder may be used.

Product arising from burning: Products of combustion may contain oxides of carbon,

hydrogen chloride and hydrogen fluoride gas.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Apply a dispersing agent, work into an emulsion with water.

Run to waste, diluting greatly with water.

Alternatively mix with a suitable absorbent material and

dispose of according to local regulations.

Handling and storage

Handling: Observe the usual precautions for handling organic

chemicals. Avoid inhalation and contact with skin and eyes.

Rubber or plastic gloves and safety goggles should be worn.

Storage: Store in a cool place out of direct sunlight.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible

Industry - Possibility of neutralisation: Not applicable, no known hazardous properties

Industry - Possibility of destruction: controlled discharge: Dispose of at a suitable landfill site (A650)

Industry - Possibility of destruction - incineration: Incinerate at a suitable facility. Waste gas treatment to

remove hydrogen chloride and hydrogen fluoride gas should be

fitted (A661)

Industry - Possibility of destruction - water purification: Not recommended

Public at large - Possibility of destruction: controlled discharge: The substance will not enter the public domain