Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: DIN EN 13016
Version / remarks:
Triple Expansion Method
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2015
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Specific details on test material used for the study:
Test guideline: DIN EN 13016
Method: Triple Expansion Method
Apparatus: Minivap VP/VPL-Vision, Grabner Instruments

Results and discussion

Vapour pressureopen allclose all
Key result
Temp.:
20 °C
Vapour pressure:
12.9 hPa
Key result
Temp.:
50 °C
Vapour pressure:
40.5 hPa

Applicant's summary and conclusion

Conclusions:
Vapor Pressure
DIN EN 13016
Triple Expansion Method
12.9 hPa @ 20°C
40.5 hPa @ 50°C