Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
hydrolysis
Type of information:
other: SIDS
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data

Data source

Referenceopen allclose all

Reference Type:
publication
Title:
SIDS for L-Glutamic acid
Author:
OECD
Year:
2013
Report date:
2013
Reference Type:
study report
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
no guideline followed

Test material

Specific details on test material used for the study:
- Name of test material (as cited in study report): 1-Aminopropane-1,3-dicarboxylic acid
- Molecular formula: HO2CCH2CH2CH(NH2)CO2H
- Molecular weight: 147.13
- Purity:>=99.5
- Lot No.: 1371820
- Storage condition of test material: Room temperature
- Supplier: Sigma-Aldrich

Results and discussion

Details on results:
As a result of the stability of test substance for 48 hours in Elendt M4 medium, the precision was 0.48-3.71%, and the variation of initial concentration was -17.48%.

Applicant's summary and conclusion

Conclusions:
L-Glutamic acid solution was stable in Elendt M4 for 48 hours.