Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019-03-28
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study performed to EU Method with no significant deviations.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Specific details on test material used for the study:
Batch No.: A03-18-0081
Purity: ≥99.9%
Key result
Flash point:
> 93 °C
Atm. press.:
102.2 kPa
Interpretation of results:
other: not classified
Conclusions:
The flash point of test item was higher than 93 °C.
Executive summary:

The flash point of the test item was determined with close-cup flash point tester according to EU Method A.9 (Flash-Point).

Based on the results, the flash point of test item was higher than 93.0 °C at 102.2 kPa.

Description of key information

The flash point of test item was higher than 93.0 °C at 102.2 kPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
93 °C

Additional information

The flash point of the test item was determined with close-cup flash point tester according to EU Method A.9 (Flash-Point).

Based on the results, the flash point of test item was higher than 93.0 °C at 102.2 kPa.