Description of key information

The vapour pressure of the test item cyclic Glucamide 810 was calculated by interpolation and extrapolation of the measured vapour pressure curve for the temperatures 20, 25 and 50 °C, according to Regulation EC 440/2008 Method A.4. Vapour Pressure and OECD Test Guideline No. 104 (2006).

Table: vapour pressure of cyclic Glucamide 810

Temperature (°C) vapour pressure (Pa)
 20  3.7 x 10-4
 25 5.3 x 10-4
 50 2.8 x 10 -3

Key value for chemical safety assessment

Vapour pressure:
0.001 Pa
at the temperature of:
25 °C