Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jul 30 - Sep 09, 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
Version / remarks:
October 9, 2017
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: DB-ALM Protocol No. 164: Ocular Irritation Assay for Chemicals using EpiOcular™ EIT,
Version / remarks:
September 14, 2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EpiOcular Eye Irritation Test (OCL-200-EIT) for the prediction of acute ocular irritation of chemicals; For use with MatTek Corporation`s Reconstructed Human EpiOcular Model; MatTek Corporation
Version / remarks:
June 29, 2015
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Bis-biphenyl-4-yl-(9,9‘-spirobifluoren-4-yl)-amine
Cas Number:
1450933-43-3
Molecular formula:
C49 H33 N
IUPAC Name:
Bis-biphenyl-4-yl-(9,9‘-spirobifluoren-4-yl)-amine
Test material form:
solid
Specific details on test material used for the study:
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: Before application, the test item was pre-warmed to 37°C to get a liquid, which was applied neat to the tissues..

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
TEST MATERIAL: 50 µL per tissue

NEGATIVE / VEHICLE CONTROL: 50 µL per tissue

Sterile deionized water was used as negative control.


POSITIVE CONTROL: 50 µL per tissue

Designation: Methyl acetate
Supplier: Merck KGaA
Lot-No.: S7451611
Catalog #: 8.09711
Purity (GC): 99.6%
Appearance: Liquid
Expiration date: June 30, 2022
Storage: 15 to 25°C

Duration of treatment / exposure:
30 ± 2 minutes
Number of animals or in vitro replicates:
in vitro: duplicate design

Results and discussion

In vitro

Results
Irritation parameter:
other: Viability %
Run / experiment:
Run 1 / Experiment 1
Value:
76.2
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
OTHER EFFECTS:
- Visible damage on test system: No observations

ACCEPTANCE OF RESULTS:
1. The negative control OD is >0.8 and <2.5 (2.086 and 2.183).
2. The mean relative viability of the positive control is below 50% of the negative control viability (13.1%).
3. The difference of viability between the two relating tissues of a single chemical is <20% (values between 0.6% to 6.3%) in the same run (for positive and negative control tissues and tissues of single chemicals).

The study met all acceptance criteria

Any other information on results incl. tables

   Mean OD  Mean Viability
 Negative Control 2.135 100.0% 
 Positive Control 0.280 13.1%
 Test Item 1.626 76.2%

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is identified as not requiring classification and labeling according to UN GHS (No Category).
Executive summary:

This study was performed according to GLP and the methods applied are fully compliant with OECD TG 492. Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is identified as not requiring classification and labeling according to UN GHS (No Category).