Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 12, 2018 to April 25, 2018
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
Deviations:
no
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
Exxate 1300: Savant ID S20180412-009

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
345 °C
Atm. press.:
742 mm Hg
Remarks on result:
other:
Remarks:
Ignition Delay Time: 2.0 seconds

Applicant's summary and conclusion

Conclusions:
The autoignition temperature for acetic acid, c11-14-isoalkyl ester, c13 rich according to ASTM E659 was 345 degrees C.