Registration Dossier

Administrative data

Endpoint:
flash point, other
Remarks:
combustible liquid, non-flammable
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 6, 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
GLP was not followed.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM D-92
Deviations:
not specified
GLP compliance:
no
Type of method:
open cup
Remarks:
Equilibrium method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
Purity of test material was 99.7% with no identified impurities. The Test material lot number was Lot No. 185110122. The test material was stored at ambient temperature.

Results and discussion

Flash point
Key result
Flash point:
>= 132 - <= 132 °C
Atm. press.:
>= 1 - <= 1 atm

Applicant's summary and conclusion